Installation
3A0537M
7
Stand Mount
Mount the pump in the accessory pump stand (B). Use
Part No. 218742 Stand for 3000 and 4000cc Pumps
(see F
IG
. 2, page 9).
See
Mounting Stand Hole Layout
on page 18. Secure
the stand to the floor with M19 (5/8 in.) bolts which
engage at least 152 mm (6 in.) into the concrete floor to
prevent the pump from tipping.
Wall Mount
1.
Ensure the wall is strong enough to support the
weight of the pump assembly and accessories, fluid,
hoses, and stress caused during pump operation.
2.
Ensure that the mounting location has sufficient
clearance for easy operator access.
3.
Position the wall bracket at a convenient height,
ensuring that there is sufficient clearance for the
fluid suction line and for servicing the lower.
4.
Drill four 7/16 in. (11 mm) holes using the bracket as
a template. Use any of the three mounting hole
groupings in the bracket. See
255143 Wall Mount
Bracket
, page 19.
5.
Bolt the bracket securely to the wall using bolts and
washers designed to hold in the wall’s construction.
6.
Attach the pump assembly to the mounting bracket.
7.
Connect air and fluid hoses.
Plumbing
Install a fluid shutoff valve (D) between the mix tank (A)
and the pump.
When using a stainless steel pump, use stainless steel
plumbing to maintain a corrosion-resistant system.
Flush Before Using Equipment
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid con-
taminating your fluid with oil, flush the equipment with a
compatible solvent before using the equipment. See
Flushing
, page 11.