background image

Contents

309524L

3

Contents

Models   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Manual Conventions   . . . . . . . . . . . . . . . . . . . . . . . . 3

Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Selecting Tubing   . . . . . . . . . . . . . . . . . . . . . . . . . 7

Mounting Heater  . . . . . . . . . . . . . . . . . . . . . . . . . 8

Fluid Connections & Accessories  . . . . . . . . . . . . 9

Electrical Connections . . . . . . . . . . . . . . . . . . . . 10

Determining Proper Fluid Temperature  . . . . . . . 12

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Pressure Relief Procedure   . . . . . . . . . . . . . . . . 14

Initial Flushing  . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Priming System  . . . . . . . . . . . . . . . . . . . . . . . . . 14

Setting Heater Control . . . . . . . . . . . . . . . . . . . . 15

Adjusting for Spraying  . . . . . . . . . . . . . . . . . . . . 15

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Flushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Draining Heater  . . . . . . . . . . . . . . . . . . . . . . . . . 16

Unclogging Fluid Passages  . . . . . . . . . . . . . . . . 16

Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Repair  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Primary Thermostat & Probe . . . . . . . . . . . . . . . 18

Backup Thermostat  . . . . . . . . . . . . . . . . . . . . . . 18

Thermal Limit Sensor   . . . . . . . . . . . . . . . . . . . . 20

Control Knob  . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Heater Block   . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Parts   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Hazardous Location Heaters  . . . . . . . . . . . . . . . 22

Non-Hazardous Location Heaters  . . . . . . . . . . . 24

Accessories   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Technical Data   . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Translations   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Graco Standard Warranty   . . . . . . . . . . . . . . . . . . . 30

Graco Information   . . . . . . . . . . . . . . . . . . . . . . . . . 30

Translations

Manual available in following languages: 

Manual Conventions

Warning

Caution

Note

Important

Manual

Language

309524

English

309555

French

309556

Spanish

309557

German

309558

Swedish

309605

Chinese

309606

Korean

309607

Japanese

WARNING

A warning alerts you to possible serious injury or 
death if you do not follow instructions.

Symbols, such as fire and explosion (shown), alert you 
to a specific hazard and direct you to read the indi-
cated hazard warnings (pages 4-5).

CAUTION

A caution alerts you to possible equipment damage or 
destruction if you do not follow instructions.

A note indicates additional helpful information.

An arrow indicates important information.

Summary of Contents for VISCON HP 245848

Page 1: ...7250 psi 50 MPa 500 bar Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions See page 2 for model numbers descriptions and a...

Page 2: ...additional information 245863 A 240 4000 16 7 245864 A 480 4000 8 30 245862 A 200 4000 20 0 Approved Exd II T2 482 F 250 C Certificate No ISSeP 07ATEX034X Approved to EN 60079 0 2006 IEC 60079 0 2004...

Page 3: ...ardous Location Heaters 24 Accessories 26 Technical Data 28 Dimensions 28 Translations 29 Graco Standard Warranty 30 Graco Information 30 Translations Manual available in following languages Manual Co...

Page 4: ...t and paint fumes in work area can ignite or explode To help prevent fire and explosion Use equipment only in well ventilated area Eliminate all ignition sources such as pilot lights cigarettes and pl...

Page 5: ...safety regulations BURN HAZARD This equipment is used with heated fluid which can cause equipment surfaces to become very hot To avoid severe burns Do not touch hot fluid or equipment Allow equipment...

Page 6: ...ilter C Air Regulator and Gauge D Air Line Lubricator E Pump Runaway Valve F Ground Wire G Pump H Explosion Proof Power Switch J Power Cable K Heater L Fluid Filter M Drain Valve N Fluid Pressure Regu...

Page 7: ...metal surfaces Insulate and or label lines and components exiting heater that may become hot Chart Notes The greater the flow rate the less the heat loss Foam insulated steel tubing and high pres sur...

Page 8: ...k washer NN not supplied to secure the bracket to the wall The heater has a surface temperature of T2 482 F 250 C Follow temperature code when locating heater See Technical Data page 28 for more tempe...

Page 9: ...a properly sized accumulator down stream from the heater Install a pressure relief valve X pre set to relieve pressure when it exceeds the system maximum working pressure 3 Install a fluid filter L dr...

Page 10: ...readed metal conduits 2 Unused threaded holes must be sealed by certified flameproof plugs which must be screwed in with a minimum of 5 full threads engaged and an 8 mm length of engaged threads WARNI...

Page 11: ...a properly grounded power supply through the electrical connections and external ground ing lug 8 In a mobile installation also ground the truck or trailer to a true earth ground FIG 7 Wall Mounted Wi...

Page 12: ...sample in the water 4 At every 10 temperature rise measure and record the viscosity and temperature Do this until solvents start boiling off and the viscosity starts to level off usually 160 170 F 71...

Page 13: ...than the enamel This means the high solid fluid is temperature sensitive and you need to take this into consideration when planning your system Once the fluid is reduced to about 34 on the chart vis...

Page 14: ...hich needs to be flushed out before using the equipment Ensure main power is off and heater is cool before flushing Use a compatible solvent and follow flushing instructions in your fluid supply and s...

Page 15: ...tch the desired tem perature adjust the setpoint Adjusting for Spraying 1 Adjust pump pressure and heater setpoint to the lowest settings needed for good fluid atomization 2 Set all system back pressu...

Page 16: ...lvent Draining Heater FIG 12 1 Follow Pressure Relief Procedure page 14 2 Remove heater inlet and outlet fittings Have a con tainer ready to catch the fluid Unclogging Fluid Passages FIG 13 1 Drain th...

Page 17: ...Adjust setting Page 15 Flow rate too high Reduce flow rate or use 2 heaters Clogged fluid passages Flush regularly Page 16 Temperature too high Wrong temperature setting Adjust setting Page 15 Failed...

Page 18: ...t probe in the heater block 3 11 Continue reassembling in reverse order of disas sembly See Reassembly Notes below Backup Thermostat 1 Follow Pressure Relief Procedure page 14 2 Remove housing cover 1...

Page 19: ...FF 1 26 28 TI12335C 25 REF 19 3A 15 HH 3B REF 10 9A 9B GND L1 L2 Wiring Diagram TI12339 20 48 50 51 55 53 52 54 62 62 63 63 3 FIG 16 Thermostat Repair Non hazardous Heaters Apply thermal lubricant To...

Page 20: ...cal junction box cover 4 4 Hazardous Location Heater only In the junction box 1B disconnect the main power lead from the ter minal of the post bushing 9A Non hazardous Location Heater only Disconnect...

Page 21: ...1 2 3 4 5 1 TI2334E 6 5 18 24 29 6 5 9A 1 2 3 4 10 15 REF 3A REF 3 3A 3B 3 5 6 1 4 1B 1A 4 JJ 30 33 12 62 63 63 62 5 FIG 18 Control Repair Non hazardous Location Heaters Torque to 89 in lb 10 N m Elec...

Page 22: ...5 35 26 28 29 30 33 12 16 19 15 16 10 6 5 REF 1 1 9 2 3 7 8 5 6 32 14 43 14 36 4 3 Torque to 89 in lb 10 N m Apply sealant Apply thermal lubricant Torque nuts 62 to 10 12 in lb 1 1 1 3 N m 1 2 3 4 1 2...

Page 23: ...72 BRACKET 2 20 15B828 LIGHT HOUSING 1 21 108664 ALLEN WRENCH 6 mm 1 22 105747 ALLEN WRENCH 2 mm 1 23 101369 ALLEN WRENCH 0 0927 in 1 24 108676 PRIMARY THERMOSTAT 1 25 100032 SCREW 6 32 UNC 2A 2 26 10...

Page 24: ...10 9 5 18 47 26 28 27 35 25 29 30 33 32 2 3 31 5 6 8 16 19 16 14 36 14 43 Torque to 89 in lb 10 N m Apply sealant Apply thermal lubricant Torque nuts 62 to 10 12 in lb 1 1 1 3 N m 1 2 3 4 3 1 2 2 1 3...

Page 25: ...ACKET 2 20 15B828 LIGHT HOUSING 1 21 108664 ALLEN WRENCH 6 mm 1 22 105747 ALLEN WRENCH 2 mm 1 23 101369 ALLEN WRENCH 0 0927 in 1 24 108676 THERMOSTAT SWITCH 1 25 100032 SCREW 6 32 UNC 2A 4 26 105672 S...

Page 26: ...110160 600 V 12 Awg Extra Hard Usage Type St High Temperature 221 F 105 C rated Thermal Lubricant 110009 6 5 gram tube Cable Clamp Kit 246303 Contains a strain relief cable clamp and 5 m 221 F 105 C c...

Page 27: ...Tighten with no more than 2 in 50 mm stripped black and blue wires and 4 in 100 mm yellow green ground wire inside terminal junction box 6 Place one side of retaining clip onto retaining clip nut and...

Page 28: ...of Part 1 of the Canadian Electrical Code Read and comply with the requirements of these and similar codes as to proper location of the heater Maximum Working Pressure 7250 psi 50 MPa 500 bar Voltage...

Page 29: ...Dimensions 309524L 29 Dimensions Measurements inches mm L K G H J 1 2 npt m Fluid Inlet 1 2 npt f Fluid Outlet 3 4 npt f Electrical Conduit Port G H J K L 9 375 238 8 46 215 6 5 165 18 457 6 375 162...

Page 30: ...se any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF...

Reviews: