Installation
309476B
5
Installation
General Information
•
. 3 on page 7 is only a guide for installing system
components and accessories. It is not an actual sys-
tem design. Contact your Graco distributor for assis-
tance in designing a system to suit your particular
needs.
•
Always use Genuine Graco Parts and Accessories,
available from your Graco distributor. If you supply
your own accessories, be sure they are adequately
sized and pressure-rated for your system.
•
Reference numbers and letters in parentheses refer
to the reference numbers in the figures and the
parts list on page 24.
Mounting the Pump
For ease of operation and service, mount the pump so
the air inlet, fluid inlet, and fluid outlet ports are easily
accessible. The inlet port must point down and the outlet
port must point up.
Use 5/8 in. lag screws or bolts for mounting.
Wall Mount Installation
1.
Wall Mount Kit 245875 is available. See F
2.
Be sure the wall can support the weight of the
pump, bracket, hoses and accessories, as well as
the stress caused during operation.
3.
Using the wall bracket (B) as a template, drill 5/8 in.
mounting holes in the wall. See page 29 for a wall
mounting diagram. Mount the bracket 1.2-1.5 m (4-5
ft) above the floor.
4.
Attach the bracket (B) to the pump (A) with the
screws (C) and washers (D) provided in the kit.
5.
Attach the bracket to the wall. Use screws (E) that
are long enough to keep the pump from vibrating
during operation. Be sure the pump is level.
Floor Stand Installation
Floor Stand Kit 245874 is available. See F
. 2 to
assemble.
To ensure proper operation, mount the pump in a
horizontal position.
F
IG
. 1: Wall Mount Kit
F
IG
. 2: Floor Stand Installation
TI2079B
C
D
B
A
E
TI20798
Summary of Contents for TRITON 1030HP
Page 11: ...Maintenance 309476B 11...
Page 14: ...Troubleshooting 14 309476B...
Page 28: ...PerformanceCharts 28 309476B...