LC-1000 Lube System Controller

76.2

(3.00)

DIMENSIONS mm / (Inches)

114.3

(4.50)

127.0

(5.00)

114.3 (4.50)

4.8 (.19)

POWER
LUBE
FAULT
CYCLE

LUBE SYSTEM

CONTROLLER

TIME  COUNTS  REMAINING

MANUAL RUN

PRGM

ENTER

MODEL   LC-1000

MANUAL

RUN BUTTON

127.0

(5.00)

ORDERING INFORMATION

PROGRAMMING INSTRUCTIONS

The LC-1000 Controller has icons in the display to indi-
cate if the unit is in a lube ON cycle or OFF cycle and to 
show the timing mode.  They are also used to indicate 
which counter is being adjusted when programming new 
parameters.  The LCD four digit display is used to show 
the remaining time left in either an ON or OFF cycle, as 
indicated by the icons.  Timing can be done in seconds, 
minutes, hours or counts.  

A fl ashing LCD character 

indicates that the timer is in the Programming mode.

VOLTAGE

PART NUMBER

12 VDC

163-400-050

24 VDC

163-400-051

115 VAC, 50/60 Hz

163-400-052

230 VAC 50/60 Hz

163-400-053

VOLTAGE

PART NUMBER

12 VDC

572-144-644

24 VDC

572-144-645

115 VAC, 50/60 Hz

572-144-646

230 VAC 50/60 Hz

572-144-647

Replacement Board

LC-1000 Controller

PUSH BUTTONS:

There are four mini push buttons;

PRGM - Initiate Program mode, or alternate between  
    settings 

for:

 ON 

 

(Monitor 

Time)

 OFF 

 

(Pause 

Time)

 CYCLE 

 

(Switch 

Transitions)

 PUMP 

 

(Pulsed 

On 

Time)

 

S

 - Increase digit

 

X

 - Next digit select

ENTER - Enter (save) new setting and advance to 
     

next 

program 

step.

S

X

Summary of Contents for Trabon LC-1000

Page 1: ...put Loading Main Pump Load 12 VDC 230 VAC 50 60 Hz 10 Amp Relay Output External Fused by User Fault Output Signal 12 VDC 230 VAC 50 60 Hz 1 Amp Resistive Max N O Dry Isolated Contact External Fused by...

Page 2: ...MANUAL RUN SW SENSE 10 11 12 13 14 15 16 17 18 19 CYCLE SWITCH SEE NOTE 2 SW IN SW FAULT FAULT DO NOT USE FIG 2 INPUT OUTPUT DRY CONTACT SEE NOTE 1 12 VDC DO NOT USE CLOSURE OF SWITCH CONTACTS CAUSES...

Page 3: ...w the remaining time left in either an ON or OFF cycle as indicated by the icons Timing can be done in seconds minutes hours or counts A flashing LCD character indicates that the timer is in the Progr...

Page 4: ...Change the value using the S key and X key c Press the ENTER key to accept the new value The SEC MIN HR CNT icon will blink d Press ENTER to accept the time base or the S key to scroll through the tim...

Page 5: ...Volume 6 0 cu in 99 cc per hour AL 50 Pump Used 24 cu in per stroke 3 9 cc Master Divider Volume per Cycle 15 cu in 2 4 cc Cycle Interval 15 Minute 1 4 hour Used Volume per Lube Cycle 6 0 cu in 4 1 5...

Page 6: ...Press ENTER Key to accept value SEC MIN HR CNT blinks d Use S Key to scroll through choices select SEC e Press ENTER Key to accept choice OFF Icon blinks 3 OFF Pause Time a Press ENTER Key OFF TIME CO...

Page 7: ...TO 00 Non pulsed output c Press ENTER Key to accept value LCD returns to DISPLAY mode Programming is now complete To verify lube sequence initiate a manual lube cycle by pressing MANUAL RUN button NO...

Page 8: ...Reprogram Replace Circuit Board as Required Power Off Before Programming Completed Complete the Programming Process Before Removing Power Fault Light On No Cycle Input Check Cycle Switch Wiring Repair...

Reviews: