The Trabon microprocessor based LC-1000 Controller 
is a multi-use solid state controller that is dedicated to 
the operation and monitoring of intermittent operat-
ing series and parallel centralized lubrication systems 
equipped with a cycle or pressure switch for cycle 
completion feed back.

The LC-1000 monitors and schedules lubrication inter-
vals in either time or stroke/cycle basis in values rang-
ing from 1 to 9999.  Pump may be self cycling or single 
cycle type requiring a pulsed output.

Four units are available for 12 VDC, 24 VDC, 115 
VAC, or 230 VAC operation.  The LC-1000 is easy to 
program in the 

fi

 eld using four mini push-buttons.  The 

programming requires no special knowledge or training 
of computer language.  During power down or outage, 
all data is saved in EEPROM (Electrically Erasable Pro-
gramming Read Only Memory).  As power is restored, 
counting and pump status are restored to values prior 
to the loss of power.  

SPECIFICATIONS

Power Supply

115  VAC + 10%, 50/60 Hz, 1 ph
230  VAC + 10%, 50/60 Hz, 1 ph
  12  VDC + 10%
  24  VDC + 10%

Output Loading

Main Pump Load:  ..........12 VDC – 230 VAC, 50/60 Hz
      10 Amp Relay Output (External Fused by User)

Fault Output Signal: ........12 VDC – 230 VAC, 50/60 Hz
  1 Amp Resistive Max. (N.O.) 

Dry Isolated Contact 

  (External Fused by User)

Temperature Range

  Do Not Locate unit in Direct Sunlight
  Operating::  -20

O

C to 50

O

C (-4

O

F to 122

O

F)

  Storage:  -25

O

C to 60

O

C (-13

O

F to 140

O

F)

Enclosure

Plastic with Clear Cover, NEMA 4X, IP 66

Display

Supertwist LCD
Annotated 4 Digit

4 LED’s:  PWR (GN), LUBE (YW), FAULT (RD), 
CYCLE (YW)  

Stroke Input 

Maximum Input Rate:  10 hz (600 CPM)
Nominal 12 Volts for 12 VDC Version
Nominal 24 Volts for 24 VDC, 115 VAC, 230 VAC 
Versions

Selectable for either Source or Sink Solid State 
Proximity Switch or Dry Contact 10 mA Max.

Other Inputs

Cycle Switch: ........12 Volts, 

Dry Contact

, 2.5 mA Max.

         Counts 

Half 

Cycles       

Programming Selection

Output ON: ...................... 1 to 9999 Seconds, Minutes, 
            Hours, 

Counts

Output OFF:..................... 1 to 9999 Seconds, Minutes, 
            Hours, 

Counts 

Cycle Counter:  .............................Half Counts (0 to 99)
Pump: ....................................... Steady State or Pulsed
          Pulse Off Time (Prime) – 3 Seconds Fixed
          Pulse On Programmable - 0 to 99 Seconds
(Pre-Lube function is not available)

Program Entry

4 Mini Push Buttons – Program, Increase, Shift, Enter

EEPROM 

Electrically Erasable Programming Read Only Memory

LC-1000 Lube System Controller

Summary of Contents for Trabon LC-1000

Page 1: ...put Loading Main Pump Load 12 VDC 230 VAC 50 60 Hz 10 Amp Relay Output External Fused by User Fault Output Signal 12 VDC 230 VAC 50 60 Hz 1 Amp Resistive Max N O Dry Isolated Contact External Fused by...

Page 2: ...MANUAL RUN SW SENSE 10 11 12 13 14 15 16 17 18 19 CYCLE SWITCH SEE NOTE 2 SW IN SW FAULT FAULT DO NOT USE FIG 2 INPUT OUTPUT DRY CONTACT SEE NOTE 1 12 VDC DO NOT USE CLOSURE OF SWITCH CONTACTS CAUSES...

Page 3: ...w the remaining time left in either an ON or OFF cycle as indicated by the icons Timing can be done in seconds minutes hours or counts A flashing LCD character indicates that the timer is in the Progr...

Page 4: ...Change the value using the S key and X key c Press the ENTER key to accept the new value The SEC MIN HR CNT icon will blink d Press ENTER to accept the time base or the S key to scroll through the tim...

Page 5: ...Volume 6 0 cu in 99 cc per hour AL 50 Pump Used 24 cu in per stroke 3 9 cc Master Divider Volume per Cycle 15 cu in 2 4 cc Cycle Interval 15 Minute 1 4 hour Used Volume per Lube Cycle 6 0 cu in 4 1 5...

Page 6: ...Press ENTER Key to accept value SEC MIN HR CNT blinks d Use S Key to scroll through choices select SEC e Press ENTER Key to accept choice OFF Icon blinks 3 OFF Pause Time a Press ENTER Key OFF TIME CO...

Page 7: ...TO 00 Non pulsed output c Press ENTER Key to accept value LCD returns to DISPLAY mode Programming is now complete To verify lube sequence initiate a manual lube cycle by pressing MANUAL RUN button NO...

Page 8: ...Reprogram Replace Circuit Board as Required Power Off Before Programming Completed Complete the Programming Process Before Removing Power Fault Light On No Cycle Input Check Cycle Switch Wiring Repair...

Reviews: