background image

Typical Installation

312473B

7

Typical Installation

Key:

A

Pump

B

Bleed-type Master Air Line Shutoff Valve

C

Pump Air Pressure Regulator

D

Gun Air Pressure Regulator

E

Gun Fluid Pressure Regulator 

F

Air  Filter

G

Hose  Set

H

Suction Hose

I

Pump Ground Wire (required)

J

Main Air Supply Line

K

Spray Gun, Finex Airspray or HVLP

L

Bleed Type Master Air Valve

M

Air Line Moisture Drain

F

IG

. 2: Typical Installation (Finex Airspray Gun Shown)

TI10825A

A

D

K

J

C

F

B

F

L

G

H

M

I

True Earth Ground

E

Summary of Contents for TI10823A

Page 1: ... professional use only Models 289353 with Finex Airspray Gun 100 psi 7 bar 0 7 MPa Maximum Working Pressure 289354 with Finex HVLP Gun 100 psi 7 bar 0 7 MPa Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual and in your respective pump manual Save these instructions TI10823A ...

Page 2: ...mp Operation and Repair 6 Pressure Relief 6 Typical Installation 7 Setup Installation 8 Grounding 9 Flush 9 Prime 10 Spraying 11 Shutdown 11 Maintenance 12 Troubleshooting 13 Parts 14 Finex Sprayer Package 14 Dimensions 15 Technical Data 15 Graco Standard Warranty 16 Graco Information 16 Related Manuals Manual Description 308553 Husky 307 Air Operated Diaphragm Pumps 312388 Finex Gun 308325 Fluid ...

Page 3: ...SUSE HAZARD Misuse can cause death or serious injury Do not operate the unit when fatigued or under the influence of drugs or alcohol Do not exceed the maximum working pressure or temperature rating of the lowest rated system component See Technical Data in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Data in all equipment manuals Read...

Page 4: ...hen operating servicing or when in the operating area of the equipment to help protect you from serious injury including eye injury inhalation of toxic fumes burns and hearing loss This equipment includes but is not limited to Protective eyewear Clothing and respirator as recommended by the fluid and solvent manufacturer Gloves Hearing protection PRESSURIZED ALUMINUM PARTS HAZARD Do not use 1 1 1 ...

Page 5: ... fluid hose and pump Air hose is conductive and used to ground gun If adding lengths to hose be sure to use conductive hoses Fluid supply container follow local code Object being sprayed follow local code Solvent pails used when flushing follow local code Use only conductive metal pails placed on a grounded surface Do not place the pail on a nonconductive sur face such as paper or cardboard which ...

Page 6: ... trapped between it and the air motor when the valve is closed Required Components not included Main Air Supply J connects air supply from air compressor to pump Recommended Components Air line filter F removes harmful contaminants from entering the air control module and air motor Air line moisture drain valve M installed at the bottom of each air line drop to drain moisture Pump Operation and Re...

Page 7: ... Air Pressure Regulator E Gun Fluid Pressure Regulator F Air Filter G Hose Set H Suction Hose I Pump Ground Wire required J Main Air Supply Line K Spray Gun Finex Airspray or HVLP L Bleed Type Master Air Valve M Air Line Moisture Drain FIG 2 Typical Installation Finex Airspray Gun Shown TI10825A A D K J C F B F L G H M I True Earth Ground E ...

Page 8: ...w this procedure 1 Connect the air hose to the gun air regulator 2 Connect the air hose to the gun 3 Connect the gun fluid hose to fluid regulator Tighten securely 4 Connect the fluid hose to the gun Tighten securely 5 Ground the pump See Grounding page 9 6 Connect the main air supply to the bleed type air valve 7 Flush See Flush page 9 8 Prime See Prime page 10 9 Spray See Spraying page 11 TI1082...

Page 9: ...ap Clean separately 3 Place the suction tube in solvent 4 Turn off both air regulators 5 Open the bleed type air valve 6 Open the pump air regulator until the pump starts 7 When clean solvent flows without air from the gun stop spraying 8 Remove the suction tube from the solvent Continue to spray until all solvent is out of the gun 9 Close the bleed type air valve 10 Relieve pressure See Typical I...

Page 10: ... the fluid 5 Open the bleed type air valve 6 Open the pump air regulator until the pump starts 7 Adjust the fluid pressure regulator 8 Hold the gun firmly against a grounded metal pail and trigger the gun until fluid flow is steady Release the trigger The equipment is ready to spray TI10826A TI10836A TI10837A TI10834A TI10832A TI10827A TI10836A TI10837A TI10828A ...

Page 11: ... 8 in straight before falling off 3 Adjust the gun air regulator to achieve proper spray gun atomization 4 Test the spray pattern Read the fluid manufacturer s recommendations Adjust as necessary Shutdown 1 Flush See Flush page 9 2 Relieve pressure See Typical Installation page 7 TI10836A TI10837A 6 in to 8 in 152 mm to 203 mm TI10838A TI10836A TI10833A TI10839A ...

Page 12: ...lean the outside of the sprayer using a soft cloth and compatible solvent 5 Check the hoses tubes and couplings every day Tighten all fluid connections before each use 6 Clean the accessory air filter not supplied in your main air line Relieve pressure before servicing See Typical Installation page 7 TI10840A TI10834A TI10841A TI10842A TI10823A TI10830A TI10829A TI10871A ...

Page 13: ... fluid supply and prime sprayer Pump cycles at stall or fails to hold pressure at stall Worn check valves or o rings Service pump Audible air leak Worn air valve Service pump Air bubbles in fluid Loose suction line Tighten Use a compatible liquid thread sealant or PTFE tape on con nections Ruptured diaphragm Service pump Poor finish or irregular pattern Incorrect fluid or air pressure at gun See g...

Page 14: ... 115219 FITTING tee 1 4 NPT 1 11 289610 HANDLE wire pump 1 12 15R472 FASTENER hex HD flanged 1 4 2 4 13 114104 SCREW mach hex wash HD 4 15 289608 STRAINER suction line 1 16 111864 CONNECTOR male 2 17 590570 HOSE polyethylene 4ft 18 116473 VALVE vented 2 way 1 19 237686 WIRE ground assembly w clamp 1 20 289522 HOSE set bundled not shown 289353 25ft 240421 HOSE set bundled not shown 289354 25ft 21 6...

Page 15: ...53 cm TI10874A TI10873A Maximum fluid working pressure 100 psi 0 7 MPa 7 bar Maximum incoming air pressure 100 psi 0 7 MPa 7 bar Operating temperature range 40 109 F 4 4 43 C Package Weight 19 8 lbs 9 0 kg Wetted Parts Pump see related manuals page 2 Gun see related manuals page 2 Fluid Regulator see related manuals page 2 Other nylon acetal SST polyethylene ...

Page 16: ...anship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as se...

Reviews: