18
310530
Service
Removing Pump Module from 20 Liter (5 gallon)
Supply Unit
(continued)
10. Fig. 9. RTV sealant on the pump shrouds may
make it difficult to remove individual shroud
pieces (8) and (A). Using a knife or razor, scrape
the sealant off of the seams of the shrouds.
11. Fig. 9, Fig. 14 (480/575 VAC) and Fig.15
(240 VAC). Disconnect the junction box from the
pump module and ) by:
a.
Removing the cover of the junction box (9).
b.
Disconnecting the heater wires and sensor
wires that come from the pump.
c.
Removing the wires from the junction box.
d.
Disconnecting the pump’s back shroud (A) and
moving it backwards out of the way.
Fig. 9
7
8
9
A
12. Remove the follower from the pump by:
a.
Removing the sensor from the follower plate.
b.
Removing the air line from the blow-off valve.
c.
Removing the bolts from the follower adapter.
d.
Sliding off the follower.
13. Separate the pump from the air motor. Go to the
next section,
Separating the 20 Liter (5 Gallon)
Pump Module from the Air Motor
.