RotoFlex™ Pump
309586R
7
Reassembly
Reinstall RotoFlex Pump hose on plate.
1.
Kink hose as shown,
making sure dots
located on hose fitting
face each other.
2.
Slide hose onto plate
as shown below, mak-
ing sure plate slides
into slot between hex
fitting on end of hose.
3.
Align dots located on hose fitting, making sure they
are facing each other at all times to ensure the hose
does not twist during reinstallation.
4.
Reposition plate, aligning hex fittings with enclosure
openings.
5.
Remove 2 x 4 support under motor.
6.
Tighten bolt. As bolt is tightened the plate will snug
back into place.
7.
Replace shroud (6 bolts).
8.
Replace hopper.
9.
Break in new pump by running dry or with warm
water for 3-5 minutes.
ti3127a
ti3125a
ti3084a