Usage
Usage
This pump must be used as part of a SaniForce pail
or drum unloader system. Refer to the appropriate
system manuals for operation instructions of this
pump when installed in those systems.
Cleaning
WARNING
PRESSURIZED FLUID HAZARD
This equipment stays pressurized until pressure is
relieved manually. To help prevent serious injury
from moving parts, or from pressurized fluid, such
as splashing in the eyes or on skin, follow the
Pressure Relief Procedure in your system manual
when you stop pumping and before you clean,
check, or service the equipment.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when
in the work area to help prevent serious injury,
including eye injury, hearing loss, or inhalation of
toxic fumes.
This procedure involves thoroughly disassembling
and cleaning the individual parts in the pump lower
unit. Prior to performing this procedure, flush the
pump and relieve pressure as described in the
system manuals, disconnect all hoses, and remove
the pump from the system.
Notes:
• Be sure to follow your national and state sanitary
standard codes and local regulations.
• Use appropriate cleaning and disinfecting agents,
at intervals appropriate for product processed.
• Follow cleaning product manufacturer’s
instructions.
• The pump must be disassembled to thoroughly
clean it.
1. Loosen the hand screw (13) and remove the
upper shield (6).
2. Clean thoroughly the surface between the upper
and lower shields.
3. Disassemble the fluid pump. See
Priming Piston Service, page 5
.
4. Wash all pump parts with an appropriate cleaning
solution at the cleaning product manufacturer’s
recommended temperature and concentration.
5. Rinse all pump parts again with water and allow
them to dry.
6. Inspect all pump parts and reclean if needed.
NOTE: Any damaged rubber parts must be
replaced as they could harbor microorganisms
that can contaminate the fluid.
7. Immerse all pump parts in an appropriate
sanitizer before assembly. Take the pump parts
out of the sanitizer one-by-one as needed.
8. Lubricate the moving pump parts and o-rings,
packings, and seals with appropriate waterproof
sanitary lubricant.
9. Circulate the sanitizing solution through the pump
and the system prior to use.
4
3A5564A
Summary of Contents for SaniForce
Page 3: ...Related Manuals 3A5564A 3 ...