Pressure Relief, page 7
Problem
Cause
Solution
Sprayer won’t run or stops intermit-
tently
Power switch not on
Turn switch on.
No power at wall outlet
Check outlet by plugging in another
appliance. If appliance does not
work, try another outlet.
Wrong size generator
Use a 7500 watt or larger generator.
Refer to Generator Requirements,
page 8.
Temperature too cold
Allow unit to warm up.
Too many items on same circuit
Unplug other items from circuit.
Internal thermal switch tripped
Self-resetting. Allow unit to cool down
15 minutes and restart. Usually
occurs when wrong size extension
cord is used.
Extension cord too long or wrong
gauge
Use a 12 gage extension cord or
remove extension cord. Refer to
Grounding and Electric Require-
ments, page 7.
Breaker tripped
Reset breaker.
Pump won’t pump material or low
output
Air lock
Open air valve on gun.
Mix too thick
Add water to thin material. Use Mate-
rial Thickness Gauge.
Loose fittings
Check and retighten all fittings.
Plugged gun
Relieve Pressure,
page 7. Remove
gun from hose. Clean gun.
RotoFlex HD Pump worn out
Replace hose.
Pump cold or material frozen in pump Move pump to warm room and allow
it to warm up or run hot water through
sprayer.
Sensor is bad
Replace, page 26
Check air system for leaks
Remove shroud and examine for air
leaks
Loose wire
Remove shroud and examine wiring
No air pressure
Rebuild compressor
Soft start won’t work/pump, always
loaded
Sensor is bad
Change sensor, page 26
Air leak due to bad seal keeps valve
open
Replace seal
Normal soft start system delay
Release trigger for 10-15 seconds.
Retry.
Switch is not operating properly
Replace switch
Damaged solenoid valve on cylinder
Check gun supply, hose and sprayer
for leaks
AIr leak
Summary of Contents for RTX 1500 248201