Compressor
12
311772G
Compressor
Use Compressor Repair Kit, 288612.
Disassembly
1.
Relieve Pressure,
page 6.
2.
Unplug sprayer from outlet.
3.
Remove
Shroud
, page 7.
4.
Remove
RotoFlex
™
II Pump
hose; page 9 or 10.
5.
Unscrew and remove grounding screw (49) from
compressor.
6.
Use 9/16 in. socket and wrench to remove pivot bolt
(26) and nut (27).
7.
Unscrew and remove second 1/2 in. grounding
screw (49) from bracket (21).
8.
Remove 4 screws (29) and lift bracket (21) off of
compressor.
9.
Remove shoulder bolt (49) holding pump roller in
place.
10. Use a wrench to push down on push-to-connect
fittings and pull out all nylon hoses.
11. Disconnect all electrical wire connectors, see
Wiring Diagram
, page 27.
12. Thoroughly clean inside housing, removing dust and
debris.
To service the compressor, remove it from the sprayer
body and place it a vice. Tighten the vice onto the main
pulley to hold the compressor in place while servicing.
ti2810b
49
ti8941a
ti8878a
26
27
49
ti9013a
ti8877a
29
21
ti8879a
49
ti8952a
ti8951a