Troubleshooting
28
334603E
Electrical
Symptom: Sprayer does not run, stops
running, or will not shut off.
Perform
1.
Plug sprayer into correct voltage,
grounded outlet.
2.
Turn the ON/OFF switch
OFF
wait 30
seconds and then turn power back
ON
again (this ensures sprayer is in normal
run mode).
3.
Turn pressure control knob clockwise
1/2 turn.
4.
View digital display or remove control
box cover to view control board status
light. To determine which code (or any
other code besides voltage supply)
refer to the control board status light.
Turn the ON/OFF switch
OFF
, remove
the control cover then turn power back
ON
. Observe the status light. Blinking
LED total count equals the error code
(for example: two blinks equals CODE
02).
Keep clear of electrical and moving parts
during troubleshooting procedures. To
avoid electrical shock hazards when
covers are removed for troubleshooting,
wait 7 seconds after disconnecting power
cord for stored electricity to dissipate.
Problem
What to Check
How to check
Sprayer does not run at all
AND
Display is blank
OR
Control board status light never lights
See flow chart, page 34.
Sprayer does not shut off
AND
Display shows E=02
OR
Control board status light blinks 2
times repeatedly
Control board.
Replace control board.