If the system produces the T6DH Sensor Error Hose
alarm or the T6DT Sensor Error TCM alarm, use
manual hose heat mode until the hose RTD cable or
FTS temperature sensor can be repaired.
Do not use Manual Hose Mode for extended periods
of time. The system performs best when the hose has
a valid RTD signal and can operate in temperature
control mode. If a hose RTD breaks, the irst priority
is to ix the RTD. Manual Hose Mode can help inish
a job while waiting for repair parts.
Enable
Enable
Enable Manual
Manual
Manual Hose
Hose
Hose Mode
Mode
Mode
1. Disconnect the hose RTD sensor from the TCM.
2. Enter Setup Mode and navigate to System
Screen 2.
3. Select Enable Manual Hose Mode.
NOTE:
NOTE:
NOTE: When manual hose mode is enabled, the
manual hose mode advisory EVCH-V will appear.
4. Enter Run Mode and navigate to the Target
screen. Use the up and down arrows to set the
desired hose current.
Hose
Hose
Hose Current
Current
Current Settings
Settings
Settings Hose
Hose
Hose Current
Current
Current
Default
20A
Maximum
37A