background image

Installation

3A4386C

9

Typical Installation

F

IG

. 2 is an example of an installation with a Python 

chemical injection pump. Your installation may differ 
from what is shown here. (See 

Required Accessories

page 8.) The Python pump (F) is the only component in 
F

IG

. 2 supplied by Graco. All other components are sup-

plied by customer.

Key:

A

Main Air Supply Line

B

Air Shutoff Valve

C

Air  Filter

D

Bleed-type Master Air Valve

E

Air Pressure Regulator

F

Pump

G

Manifold Assembly (includes y-strainer and fluid shutoff 
valve (H))

H

Fluid Shutoff Valve (inlet & outlet)

J

Fluid Pressure Relief Valve

K

Fluid Inlet Line

L

Inlet  Port

M

Outlet  Port

N

Air Lubricator

P

Fluid Outlet Line

Mount the Pump and Connect 
Chemical Supply

If you have an application, or mounting configuration, 
that requires installation in a manner different than 
depicted in F

IG

. 2, please contact your Graco distributor 

for assistance.

NOTE:

 A y-strainer (G) or chemical filter is required 

before the pump inlet. This will keep any debris from the 
tank from reaching the pump seals. Fluid filters are 
available from Graco. See 

Kits and Accessories

 on 

page 42.

1.

Mount the pump (F) and connect the fluid inlet 
line (K).

The pump is designed to be vertically mounted directly 
from the 1/4 female NPT inlet port (L). The inlet port (L) 
is on the bottom and is designated by a flow arrow point-
ing into the pump. Verify the inlet plumbing is sufficiently 
strong to support the weight of the pump.

F

IG

. 2: Typical Installation

Torque to ----

Torque to ----

A

C

E

B

D

F

J

K

H

G

L

M

N

H

P

Summary of Contents for Python A25150

Page 1: ...oval Pneumatic pump for injecting chemicals at well sites For use with compressed air only For professional use only See page 3 for model information including maximum working pressures Important Safety Instructions Read all warnings and instructions in this manual Save all instructions II 2 G c T6 ...

Page 2: ... Procedure 17 Flush the Equipment 17 Prime the Pump 18 Calibrate Chemical Dosage 19 Maintenance 22 Preventive Maintenance Schedule 22 Tighten Threaded Connections 22 Tighten Packings 22 Storage 22 Troubleshooting 23 Repair 24 Pump 24 Check Valves 29 Timing Valve 32 Parts 36 Python Pneumatic Pump 36 Python Timing Valve Assembly 40 Kits and Accessories 42 Dimensions 43 Python Pump Dimensions 43 Perf...

Page 3: ...1 40 14 0 1 4 in 3500 24 1 241 3 8 in 1500 10 3 103 1 2 in 875 6 0 60 5 8 in 500 3 4 34 3 4 in 400 2 8 28 1 8 in 1 3 4 in 12 000 82 7 827 87 0 60 6 0 3 16 in 12 000 82 7 827 163 1 12 11 2 1 4 in 7000 48 3 483 200 1 40 14 0 3 8 in 3000 20 6 206 1 2 in 1750 12 1 121 5 8 in 1000 6 9 69 3 4 in 800 5 5 55 1 8 in 2 in 12 000 82 7 827 66 0 46 4 6 3 16 in 12 000 82 7 827 125 0 86 8 6 1 4 in 9500 65 5 655 ...

Page 4: ...32240 can be used to convert HF4 outlet connec tion to 1 4 in NPT F for applications 10 000 psi and under PCI 125 19 S X A A Pneumatic Chemical Injection Air Motor Size Plunger Size Pressure Range Plunger Material Seal Material Qualifier Air Motor Size Plunger Size Pressure Range Plunger Material Seal Material Qualifier 125 1 1 4 inch 13 1 8 Diameter S StandardPressure 1 4 3 8 1 2 5 8 3 4 plungers...

Page 5: ...hen flammable fumes are present Use only grounded hoses Stop operation immediately if static sparking occurs or you feel a shock Do not use equipment until you identify and correct the problem Keep a working fire extinguisher in the work area SKIN INJECTION HAZARD High pressure fluid from dispensing device hose leaks or ruptured components will pierce skin This may look like just a cut but it is a...

Page 6: ...ed parts See Technical Data in all equipment manuals Read fluid and solvent manufacturer s warnings For complete information about your material request Safety Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use Check equipment regularly Repair or replace worn or damaged parts immediately with genuine man ufacture...

Page 7: ...orrespond to the numbers in the Parts Lists starting on page 36 Key FIG 1 Pump Components 21 8 12 1 20 13 17 22 18 1 Air Motor Housing 8 Air Piston Cylinder 12 Dust Shield 13 Fluid Cylinder 17 Inlet Valve Check 18 Outlet Valve Check 20 Priming Bleed Valve 21 Pump Stroke Adjuster 22 Timing Valve ...

Page 8: ...ose to the pump Air line filter C removes harmful dirt and mois ture from compressed air supply Second bleed type air valve air shutoff valve B isolates air line accessories for servicing Locate upstream from all other air line accessories Fluid Line Fluid filter Y Strainer included in G with a 60 mesh 250 micron stainless steel element to filter particles from the fluid before in reaches the pump...

Page 9: ...utlet Line Mount the Pump and Connect Chemical Supply If you have an application or mounting configuration that requires installation in a manner different than depicted in FIG 2 please contact your Graco distributor for assistance NOTE A y strainer G or chemical filter is required before the pump inlet This will keep any debris from the tank from reaching the pump seals Fluid filters are availabl...

Page 10: ...umatic line to the 1 8 in female NPT port 116 on the timing valve See Python Timing Valve Assembly page 40 An 1 8 in NPT fitting is preferred though a 1 8 in 1 4 in NPT adapter is included for convenience Connect Chemical Outlet 1 Connect a 1 4 npt f fluid line from the outlet check valve M to the injection point NOTE On high pressure configurations PCI xxx xxH xx x the 1 4 npt f fitting is replac...

Page 11: ... 08 10 8 80 0 55 5 5 61 0 42 4 2 5000 34 5 344 7 100 0 69 6 9 51 0 35 3 5 50 0 34 3 4 162 1 12 11 2 83 0 57 5 7 63 0 44 4 4 5250 36 2 362 102 0 70 7 0 52 0 36 3 6 50 0 34 3 4 168 1 16 11 6 86 0 59 5 9 66 0 45 4 5 5500 37 9 379 2 105 0 72 7 2 53 0 37 3 7 50 0 34 3 4 173 1 20 12 0 88 0 61 6 1 68 0 47 4 7 5750 39 6 396 4 107 0 74 7 4 55 0 38 3 8 50 0 34 3 4 179 1 23 12 3 91 0 63 6 3 70 0 48 4 8 6000 ...

Page 12: ... 4 92 0 63 6 3 70 0 48 4 8 3500 24 1 241 3 190 1 31 13 1 97 0 67 6 7 74 0 51 5 1 3750 25 9 258 6 200 1 38 13 8 102 0 70 7 0 78 0 54 5 4 4000 27 6 275 8 107 0 74 7 4 82 0 56 5 6 4250 29 3 293 112 0 77 7 7 86 0 59 5 9 4500 31 310 3 117 0 81 8 1 90 0 62 6 2 4750 32 8 327 5 122 0 84 8 4 94 0 65 6 5 5000 34 5 344 7 127 0 88 8 8 98 0 67 6 7 5250 36 2 362 133 0 91 9 1 101 0 70 7 0 5500 37 9 379 2 138 0 9...

Page 13: ...11 4 113 8 198 1 37 13 7 101 0 70 7 0 77 0 53 5 3 1800 12 4 124 1 108 0 74 7 4 83 0 57 5 7 1950 13 4 134 4 115 0 79 7 9 88 0 61 6 1 2100 14 5 144 8 122 0 84 8 4 93 0 64 6 4 2250 15 5 155 1 129 0 89 8 9 99 0 68 6 8 2400 16 5 165 5 136 0 93 9 3 104 0 72 7 2 2550 17 6 175 8 142 0 98 9 8 109 0 75 7 5 2700 18 6 186 2 149 1 03 10 3 114 0 79 7 9 2850 19 7 196 5 156 1 08 10 8 120 0 82 8 2 3000 20 7 206 8 ...

Page 14: ...3 91 0 63 6 3 69 0 48 4 8 900 6 2 62 1 194 1 34 13 4 99 0 68 6 8 76 0 52 5 2 1000 6 9 68 9 107 0 74 7 4 82 0 56 5 6 1100 7 6 75 8 115 0 79 7 9 88 0 61 6 1 1200 8 3 82 7 123 0 85 8 5 94 0 65 6 5 1300 9 89 6 131 0 91 9 1 101 0 69 6 9 1400 9 7 96 5 140 0 96 9 6 107 0 74 7 4 1500 10 3 103 4 148 1 02 10 2 113 0 78 7 8 1600 11 110 3 156 1 08 10 8 119 0 82 8 2 1700 11 7 117 2 164 1 13 11 3 126 0 87 8 7 1...

Page 15: ... 0 44 4 4 525 3 6 36 2 181 1 25 12 5 92 0 64 6 4 71 0 49 4 9 600 4 1 41 4 200 1 38 13 8 102 0 70 7 0 78 0 54 5 4 675 4 7 46 5 111 0 77 7 7 85 0 59 5 9 750 5 2 51 7 121 0 83 8 3 93 0 64 6 4 825 5 7 56 9 131 0 90 9 0 100 0 69 6 9 900 6 2 62 1 140 0 97 9 7 107 0 74 7 4 975 6 7 67 2 150 1 03 10 3 115 0 79 7 9 1050 7 2 72 4 159 1 10 11 0 122 0 84 8 4 1125 7 8 77 6 169 1 16 11 6 129 0 89 8 9 1200 8 3 82...

Page 16: ...50 2 4 24 1 176 1 21 12 1 90 0 62 6 2 69 0 47 4 7 400 2 8 27 6 194 1 34 13 4 99 0 68 6 8 76 0 52 5 2 450 3 1 31 108 0 74 7 4 83 0 57 5 7 500 3 4 34 5 117 0 81 8 1 90 0 62 6 2 550 3 8 37 9 126 0 87 8 7 97 0 67 6 7 600 4 1 41 4 136 0 93 9 3 104 0 72 7 2 650 4 5 44 8 145 1 00 10 0 111 0 76 7 6 700 4 8 48 3 154 1 06 10 6 118 0 81 8 1 750 5 2 51 7 163 1 12 11 2 125 0 86 8 6 800 5 5 55 2 172 1 19 11 9 1...

Page 17: ...nt Flush with a fluid that is compatible with the fluid being dispensed and the equipment wetted parts 1 Follow the Pressure Relief Procedure 2 Connect inlet to the supply source of the flushing fluid 3 Connect outlet to a waste reservoir 4 Run the pump until the dispensed fluid is predomi nately flushing fluid 5 Follow the Pressure Relief Procedure This equipment stays pressurized until pressure ...

Page 18: ...ve knob 122 located on the tim ing valve 22 counter clockwise slowly This will turn the pneumatic supply on to the pump and begin cycling 4 Keep the pump cycle rate less than 1 cycle every 3 seconds The pump is primed when discharge from the prime valve 20 has transitioned from air to bubbly liquid chemical to pure liquid chemical 5 Close the prime valve 20 tightly and verify that fluid has stoppe...

Page 19: ...Turning the knob 122 counter clockwise will increase the pump flow rate while turning the knob clockwise will decrease the flow 4 Repeat the test procedure to verify your changes Repeat as necessary until the desired flow rate is achieved Stroke Adjustment This pump has infinite stroke adjustment between full and 1 4 stroke and has four marked stroke adjustment positions To increase the stroke len...

Page 20: ...2 1 6 6 1 55 3 2 11 9 2 4 9 0 1 6 6 0 0 8 3 0 7 1 26 9 5 3 20 2 3 6 13 4 1 8 6 7 60 3 4 13 0 2 6 9 8 1 7 6 5 0 9 3 3 7 7 29 3 5 8 22 0 3 9 14 7 1 9 7 3 CPM 1 4 in Fluid Plunger Pumps 3 8 in Fluid Plunger Pumps GPD LPD GPD LPD Full Stroke 3 4 Stroke 1 2 Stroke 1 4 Stroke Full Stroke 3 4 Stroke 1 2 Stroke 1 4 Stroke 5 1 4 5 3 1 1 4 0 0 7 2 7 0 4 1 3 3 2 12 2 2 4 9 2 1 6 6 1 0 8 3 1 10 2 8 10 7 2 1 8...

Page 21: ...173 7 30 6 115 8 15 3 57 9 45 44 1 166 8 33 0 125 1 22 0 83 4 11 0 41 7 68 8 260 6 51 6 195 5 34 4 130 3 17 2 65 2 50 49 0 185 3 36 7 139 0 24 5 92 7 12 2 46 3 76 5 289 6 57 4 217 2 38 2 144 8 19 1 72 4 55 53 9 203 9 40 4 152 9 26 9 101 9 13 5 51 0 84 1 318 5 63 1 238 9 42 1 159 3 21 0 79 6 60 58 8 222 4 44 1 166 8 29 4 111 2 14 7 55 6 91 8 347 5 68 8 260 6 45 9 173 7 22 9 86 9 CPM 3 4 in Fluid Pl...

Page 22: ...gs included in your pump have the ability to be adjusted to stop leaks that develop when the seals are worn If a leak develops in the pump s fluid section tighten the packing nut clockwise by 1 16th of a turn or lower until the leak is eliminated The life of the packing can be affected by over tightening the packings If the packing nut needs to be tightened repeatedly after short intervals replace...

Page 23: ...ming valve Clean or rebuild timing valve Worn timing valve seals Rebuild timing valve Timing valve cycling but pump not stroking Fluid back pressure too high Verify pump is sized to back pres sure Check inlet gas pressure Packings too tight Loosen or replace packing Fluid leaking Loose fittings Tighten fittings Worn seals Adjust packing if leak persists replace packing Pump stroking but no fluid m...

Page 24: ... away from the air motor housing 1 taking great care to keep the fluid plunger 5 from contacting any metal surfaces The fluid plunger 5 will stay attached to the air motor during repair See FIG 7 and FIG 8 Before servicing or repairing your pump verify that pressure is relieved according to the Pressure Relief Procedure page 17 and that all fluid and pneumatic lines are properly shut off or sealed...

Page 25: ...d bearings 14 if neces sary Lubricate prior to reassembly 4 Reinsert the packing nut 16 packing 15 and bearings 14 into the fluid cylinder 13 Tighten hand tight and back off of a turn to prevent dam age to packing 15 during reassembly FIG 8 Remove parts from fluid cylinder 5 16 14 15 14 12 13 Seal lips facing down FIG 9 Packing 15 detailed view Tan Gray Black Tan Gray Gray ...

Page 26: ...f 15 in lbs 1 7 N m then loosen and tighten again it to a final torque of 5 in lbs 0 6 N m NOTE If a torque wrench is not present in the field an alternative method is to tighten the packing nut 16 fin ger tight through the window then use a small punch or hex wrench to further tighten by approximately 10 degrees NOTE If the packing nut 16 is over tightened the pump may not complete a full stroke ...

Page 27: ...sure on the air piston cylinder 8 as the set screws 10 are loosened 5 Carefully slide the air piston cylinder 8 away from the air motor housing 1 taking great care to keep the fluid plunger 5 from contacting any metal sur faces The fluid plunger 5 may come out with the air cylinder 8 during removal and can stay con nected to the air piston 6 during repair 6 Remove the pump piston 6 and plunger 5 a...

Page 28: ...he new plunger 5 4 Install the new plunger and tighten to 75 in lbs 8 5 N m 5 Allow thread locker to dry for 60 minutes before operating the pump Air Piston Fluid Plunger and Upper Cylinder Reassembly 1 Ensure that all parts are cleaned before reassem bly 2 Apply a thin coat of grease to the inside of the air piston cylinder 8 and piston o ring 7 and insert the piston 6 and plunger 5 assembly 3 Ap...

Page 29: ...all punch or hex wrench to further tighten by approximately 10 degrees NOTE If the packing nut 16 is over tightened the pump may not complete a full stroke and seal life will be compromised Check Valves Inlet Check Valve Repair all models except PCI xxx xxH 1 Follow the Pressure Relief Procedure page 17 2 Remove the inlet check valve assembly 17 3 Remove the retaining nut 17a and piston 17b 4 Remo...

Page 30: ...front housing 17d to the back hous ing 17e 8 Reconnect the inlet check valve assembly 17 Outlet Check Valve Repair all models except PCI xxx xxH 1 Follow the Pressure Relief Procedure page 17 2 Remove the outlet check valve assembly 18 3 Remove the retaining nut 18a spring 18b and piston 18c 4 Remove the piston o ring 18d 5 Inspect parts for wear replace as needed 6 Install the piston o ring 18d p...

Page 31: ...e the front housing 18e from the back housing 18f 4 Remove the spring 18b piston 18c and piston o ring 18d 5 Inspect parts for wear replace as needed 6 Install the piston o ring 18d piston 18c and spring 18b 7 Reattach the back housing 18f to the front housing 18e 8 Reconnect the outlet check valve assembly 18 FIG 20 Outlet check valve assembly 18e 18d 18c 18b 18f 18 ...

Page 32: ...to separate the two halves of the timing valve 101 110 Inspect the three face seal o rings 106 and replace as neces sary 5 Pull the spool 103 out of the lower housing 101 Inspect and replace as necessary 6 Remove all of the seal cartridge components by hooking the radial ports with a plastic pick Take care not to scratch or damage any of the metal or plastic parts Sealing can be compromised FIG 21...

Page 33: ...seals factory installed 10 Remove the control knob 122 by loosening the two hex set screws 123 with a 1 16 hex key wrench 11 Remove the knob control spring 120 and the retaining ring 119 12 Remove the needle valve 117 by unscrewing it from the housing 110 Inspect the sealing o ring 118 and replace as necessary 13 Clean and inspect all parts before reassembly 14 Apply a thin coat of grease to the o...

Page 34: ...8 They are designed to operate without grease 18 Reinstall the seal cartridges see FIG 23 for the order of the seals 105 and o rings 124 into the lower housing 101 Apply a thin coat of grease on the housing lead in 130 to ease installation and ensure that the seals are not damaged 19 Reinstall the spool 103 carefully through the seal cartridge components FIG 26 Align timing valve knob with label 1...

Page 35: ...ct all fluid lines 2 Reconnect the timing valve 22 onto the pump assembly 3 Reconnect all pneumatic lines 4 Prime the Pump on page 18 5 Calibrate Chemical Dosage on page 19 to test for proper pump operation The calibration test will ensure the desired pump stroke is achieved as well as verify proper operation of the check valves 6 Compare results from calibration test with previous notes or the re...

Page 36: ...Parts 36 3A4386C Parts Python Pneumatic Pump PCI 200 13S SA A shown 1 2 3 4 5 6 7 8 10 11 12 27 14 14 15 16 17 20 19 18 21 22 9 13 33 25 ...

Page 37: ...der 2 00 1 9 B32163 Retaining ring included with air motor housing ref 1 1 10 B32175 Set screw included with air motor housing ref 1 3 11 B32176 O ring packing for 1 2 and smaller fluid plungers included with dust shield ref 12 1 B32177 O ring packing for 5 8 and larger fluid plungers included with dust shield ref 12 1 12 B32178 Dust shield for 1 2 and smaller fluid plungers 1 B32179 Dust shield f...

Page 38: ...B32247 1 Ref Part Numbers by Fluid Plunger Size Diameter Qty 1 8 in 3 16 in 1 4 in 3 8 in 1 2 in 5 8 in 3 4 in 13 B32180 B32181 B32182 B32183 B32184 B32185 B32180 1 Ref Part Numbers by Fluid Plunger Size Diameter Qty 1 8 in 3 16 in 1 4 in 3 8 in 1 2 in 5 8 in 3 4 in FKM 15 B32115 B32119 B32094 B32098 B32102 B32123 B32127 1 FKMETP 15 B32116 B32120 B32095 B32099 B32103 B32124 B32128 1 HNBR 15 B32117...

Page 39: ...6 B32026 B32026 B32026 1 HNBR 17 B32230 B32230 B32220 B32113 B32113 B32113 B32113 1 FFKM 17 B32232 B32232 B32222 B32028 B32028 B32028 B32028 1 Ref Part Numbers by Fluid Plunger Size Diameter Qty 1 8 in 3 16 in 1 4 in 3 8 in 1 2 in 5 8 in 3 4 in FKM 18 B32227 B32227 B32217 B32025 B32025 B32025 B32025 1 FKMETP 18 B32229 B32229 B32219 B32027 B32027 B32027 B32027 1 HNBR 18 B32231 B32231 B32221 B32114 ...

Page 40: ...Parts 40 3A4386C Python Timing Valve Assembly B32069 101 102 103 104 105 106 107 108 110 111 112 113 114 105 115 116 117 120 119 118 122 123 125 124 130 102 129 109 124 124 124 105 105 ...

Page 41: ...ng Retainer 1 113 Dowel Pin included with lower housing ref 101 2 114 O ring included with spring retainer ref 112 1 115 B32197 Spool Return Spring 1 116 Nipple Fitting 1 8 NPT included with lower housing ref 101 1 117 B32199 Timing Valve Needle 1 118 O ring included with timing valve needle ref 117 1 119 Internal Ring Stainless Steel included with timing valve nee dle ref 117 1 120 Knob Spring in...

Page 42: ... and piston o rings B32039 FKM ETP Large 3 8 3 4 Inlet and Out let Check Valve Repair Kit includes a spring and piston o rings B32040 FFKM Large 3 8 3 4 Inlet and Outlet Check Valve Repair Kit includes a spring and piston o rings B32111 HNBR Large 3 8 3 4 Inlet and Outlet Check Valve Repair Kit includes a spring and piston o rings B32870 TFE P Large 3 8 3 4 Inlet and Outlet Check Valve Repair Kit ...

Page 43: ...Dimensions 3A4386C 43 Dimensions Python Pump Dimensions FIG 30 Python Pump Dimensions A B C D E 13 26 in 33 7 cm 5 3 in 13 5 cm 2 34 in 5 9 cm 2 3 in 5 8 cm 9 125 in 23 2 cm ...

Page 44: ...000 13 79 137 9 4000 27 58 275 8 6000 41 37 413 7 8000 55 16 551 6 10000 68 95 689 5 0 5 1 9 1 0 3 8 1 5 5 7 2 0 7 6 2 5 9 5 3 0 11 4 3 5 13 3 4 0 15 1 4 5 17 0 12000 82 74 827 4 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 D 200 1 38 13 8 ...

Page 45: ... C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 D 200 1 38 13 8 FIG 33 0 0 2000 13 79 137 9 3000 20 68 206 8 1000 6 89 68 9 2 7 6 500 3 45 34 5 1500 10 34 103 4 2500 17 24 172 4 3500 24 13 241 3 4 15 2 6 22 7 8 30 3 10 37 9 12 45 4 14 53 0 16 60 6 18 68 1 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 3...

Page 46: ...0 12 41 124 1 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 D 200 1 38 13 8 FIG 35 0 0 800 5 52 55 2 900 6 21 62 1 10 38 20 76 30 114 40 151 50 189 60 227 70 265 80 303 100 0 69 6 9 200 1 38 13 8 300 2 07 20 7 400 2 76 27 6 500 3 45 34 5 600 4 14 41 4 700 4 83 48 3 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI M...

Page 47: ...C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 D 200 1 38 13 8 FIG 37 0 20 76 40 151 60 227 80 303 100 379 120 454 140 530 160 606 180 681 0 50 0 35 3 5 100 0 69 6 9 150 1 03 10 3 200 1 38 13 8 250 1 72 17 2 300 2 07 20 7 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10...

Page 48: ... 8 1 5 5 7 2 0 7 6 2 5 9 5 3 0 11 4 3 5 13 3 4 0 15 1 A B Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 FIG 39 0 0 2000 13 79 137 9 4000 27 58 275 8 6000 41 37 413 7 8000 55 16 551 6 10000 68 95 689 5 12000 82 74 827 4 1 3 8 2 7 6 3 11 4 4 15 2 5 19 0 6 22 7 7 26 5 8 30 3 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 ...

Page 49: ... 41 37 413 7 7000 48 26 482 6 Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 D 200 1 38 13 8 FIG 41 0 0 5 19 10 38 15 57 20 76 25 95 30 114 35 133 40 151 45 170 2000 13 79 137 9 3000 20 68 206 8 1000 6 89 68 9 500 3 45 34 5 1500 10 34 103 4 2500 17 24 172 4 3500 24 13 241 3 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI M...

Page 50: ...79 137 9 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 D 200 1 38 13 8 FIG 43 0 20 76 40 151 60 227 80 303 100 379 120 454 0 200 1 38 13 8 400 2 76 27 6 600 4 14 41 4 800 5 52 55 2 1000 6 90 69 0 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 D 200 1 38 13 8 ...

Page 51: ... 5 600 4 14 41 4 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 D 200 1 38 13 8 FIG 45 0 0 0 5 1 9 1 0 3 8 1 5 5 7 2 0 7 6 2 5 9 5 3 0 11 4 3 5 13 3 4 0 15 1 2000 13 79 137 9 4000 27 58 275 8 6000 41 37 413 7 8000 55 16 551 6 10000 68 95 689 5 12000 82 74 827 4 14000 96 53 965 3 A B Outlet Pressure PSI MPa Bar GPD LPD Inlet Press...

Page 52: ...000 82 74 827 4 14000 96 53 965 3 Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 FIG 47 0 0 2 7 6 4 15 2 6 22 7 8 30 3 10 37 9 12 45 4 14 53 0 16 60 6 18 68 1 2000 13 79 137 9 4000 27 58 275 8 6000 41 37 413 7 8000 55 16 551 6 10000 68 95 689 5 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 6...

Page 53: ...00 3 45 34 5 1500 10 34 103 4 2500 17 24 172 4 3500 24 13 241 3 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 6 9 C 150 1 03 10 3 D 200 1 38 13 8 FIG 49 0 0 10 38 20 76 30 114 40 151 50 189 60 227 70 265 500 3 45 34 5 1000 6 90 69 0 1500 10 34 103 4 2000 13 79 137 9 2500 17 24 172 4 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa...

Page 54: ... 8 27 82 7 1400 9 65 96 5 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 100 0 69 FIG 51 0 20 76 40 151 60 227 80 303 100 379 120 454 140 530 160 606 180 681 0 200 1 38 13 8 400 2 76 27 6 600 4 14 41 4 700 4 83 48 3 800 5 52 55 2 100 0 69 6 9 300 2 07 20 7 500 3 45 34 5 A B C D Outlet Pressure PSI MPa Bar GPD LPD Inlet Pressure PSI MPa Bar A 50 0 35 3 5 B 10...

Page 55: ...in npt f Fluid outlet size 1 8 3 16 plungers only HiP HF4 Prime bleed size 1 4 3 8 1 2 5 8 3 4 plungers only 10 32 UNF Prime bleed size 1 8 3 16 plungers only 1 16 in npt f Pneumatic inlet size 1 8 in npt f 1 4 npt f adapter included Pneumatic outlet size exhaust recovery 1 8 in npt f Materials of Construction Pump Check Valve Seal Material See Configuration Chart on page 4 for seal material All o...

Page 56: ... material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warra...