Pump screen 3 sets the pressure alarm limits for the
pump.
When Inlet
Inlet
Inlet Pressure
Pressure
Pressure in
is
set to Disabled, the inlet limit fields are grayed
out and only the outlet limit fields are active. See
Pressure Alarm and Deviation Limits, page 87
.
Figure 65 Pump Screen 3, Pressure Monitoring
Disabled
When Inlet
Inlet
Inlet Pressure
Pressure
Pressure in
is
set to Monitor, all fields are active. See
Pressure Alarm and Deviation Limits, page 87
.
Figure 66 Pump Screen 3, Pressure Monitoring
Enabled
Pressure
Pressure
Pressure Alarm
Alarm
Alarm and
and
and Deviation
Deviation
Deviation Limits
Limits
Limits
Inlet fields are only active if Inlet
Inlet
Inlet Pressure
Pressure
Pressure
is set to Monitor; they
are grayed out if set to Disabled. Outlet fields are
active at all times.
• Alarm and Deviation ranges are 0-300 psi for
low pressure systems, and 0-1500 psi for high
pressure systems.
• Setting to 0 will disable the alarm. The Inlet Alarm
High and Outlet Alarm High cannot
cannot
cannot be disabled.
• Alarms and Deviations will display when the inlet
or outlet pressure drops below the low limit or
exceeds the high limit.
NOTE:
NOTE:
NOTE: Outlet Alarm Low is only enabled for systems
using Flow Control.