Setup Mode
◆
Advanced Screens
310633C
35
Advanced Screens
Advanced setup has 3 screens. The screen number
appears on the right side of the screen. F
IG
. 38.
Advanced Screen 1
Language
Defines the language of the screen text. Select English
(default), French, German Spanish, Japanese (Kanji),
and Chinese (simplified).
Usage Report
Options are to take No Action or:
•
Print - sends Material Usage Report to printer.
(Totals are not cleared.) Printout is in cc or oz,
depending on Display Units setting. ProMix™ II
must be in Standby
mode.
•
Clear - Resets all color totals to zero.
Example: Material Usage Report
Display Units
Select cc/Liter (default) or oz/Gallon. Effects units used
for Run screen job totalizers, Report screen grand total
volume, and the potlife volume set on Advanced Screen
2. All other volumetric values remain as cc, cc/min., and
cc/pulse.
Dose Size
A dose is the volume of fluid that flows through the sys-
tem in one complete cycle of dispense valves A and B.
The optimal dose size depends on the mix ratio, flow
rate, and ratio tolerance of the fluid you are using.
In general, mix quality is better with smaller dose sizes.
However, due to the uncertainty of the valve timing,
smaller dose sizes can generate more off-ratio condi-
tions, especially at high flow rates. Repeated trial and
adjustment may be necessary to find the optimal dose
size and ratio tolerance.
Select from these 3 settings:
•
25 cc - (default) works well for most applica-
tions. It is small enough for good integration,
while still avoiding nuisance alarms.
•
50 cc - is best used when an application has
high fluctuations in mix ratio, such as when
using a high flow rate (> 2000 cc/min.) or flow
meters with lower resolution (K-factor > 0.2
cc/pulse).
•
Automatic - is a setting that eliminates the
need to repeatedly adjust the dose size and tol-
erance. Each time the Mix
key is pressed,
the ProMix™ II chooses between 15 cc, 25 cc,
or 50 cc dose sizes, based on how well the ratio
was maintained during the last application of the
color selected. This is especially beneficial
when using a very low flow rate (< 100 cc/min.).
Press
key to show drop-down lists and to enter your
selection.
F
IG
. 38: Setup Mode - Advanced Screen 1
Custom screen languages can be loaded, using the
ProMix™ II Data Download Kit 234668.
Screen
Number
Material Usage
Start Time: 09-Dec-2003 12:24:08
End Time: 09-Dec-2003 12:26:19
Color
A (cc)
B (cc)
1
51
17
2
0
0
3
100
25
4
20
10
5
0
0
6
0
0
Summary of Contents for ProMix II
Page 5: ...Related Manuals 310633C 5 ...