Service
◆
Smart Fluid Panel
310653D
23
Installing
9.
Screw meter (1) securely onto the dispense valve
connector (H), using a wrench.
10.
Secure meter (1) to plate (108) with screws (107).
11.
Connect meter cable (110). See F
. 21.
12.
Connect fluid line (P).
13.
Calibrate meter as instructed in ProMix™ II
Operation manual.
Servicing Fluid Manifold
Removing
1.
Follow
procedure, steps
2.
Disconnect air and fluid lines from the manifold
(17).
3.
Holding onto the fluid manifold (17), remove the 4
screws (18). To ease screw removal, use a long
T-handle Allen wrench.
4.
Remove fluid manifold (17).
5.
Service fluid manifold as instructed in the Fluid Mix
Manifold manual.
Installing
6.
Secure fluid manifold (17) to mounting plate (13)
with 4 screws (18).
7.
Install meters (1). See steps 9-11, at left.
8.
Connect air and fluid lines.
9.
Calibrate meter as instructed in ProMix™ II
Operation manual.
CAUTION
To avoid leakage, secure the meter (1) to the dis-
pense valve connector (H) before connecting it to the
plate (108).
F
IG
. 21: G3000 or G3000HR Cable Schematic
WARNING
Follow
, page 8, before
servicing equipment. Read warnings, page 6.
Common (black)
Signal (white)
Shield
Common (black)
Signal (white)
Shield
J3*
1
2
3
4
5
6
7
8
Cable
Flow Meter A
*Connector on Smart Fluid Panel circuit board
Power (red)
Power (red)
Cable
Flow Meter B
F
IG
. 22
18
Item 17
13
TI4859a