Reassemble Smart Fluid Panel
1.
Remove screws and slide the panel (14) back into
place.
2.
Secure the cover (15) and panel (14) with the 4
screws (16). F
Servicing Flow Meters
•
Coriolis Meter: To remove and service see Coriolis
meter manuals.
•
G3000 or G3000H Meter: To remove, follow proce-
dure below. To service, see meter manual.
G3000 or G3000HR Meter
Removing
1.
, page 8. Make
sure you complete step 11.
2.
Close main air shutoff valve on air supply line and
on ProMix™ II.
3.
Shut off ProMix™ II power (0 position).
4.
Unscrew cable connector (110) from meter (1). F
20.
5.
Unscrew M6 screws (107) from bottom of meter
mounting plate (108) with socket wrench. F
. 19.
6.
Unscrew fluid line from meter inlet (P).
7.
Unscrew meter (1) from dispense valve connector
(H). F
8.
Service meter as instructed in the meter manual.
F
IG
. 18
WARNING
Read warnings, page 6.
15
16
14
The meter shield (R) is unattached and may fall off
when you remove the meter (1). F
F
IG
. 19
F
IG
. 20
P
107
108
110
1
H
R