As much as possible, cables and tubing are
connected at the factory. Two additional connections
are needed for the Electrostatic Controller (21).
1.
For any installation that involves discrete
integration, connect the discrete I/O cable (49)
from the I/O cable connection on the Electrostatic
Controller to a PLC or other device. Two
discrete I/O interlock connections are supplied
and must be satisfied. See Manual 3A3657 for
detailed information on each pin and for interlock
requirements.
2.
Connect the power cord (50) to the input power
connection on the Electrostatic Controller
and secure with the connector screw. This
connection is required for all installations. The
Electrostatic Controller can operate at 100–240
VAC (50–60 Hz). Connect the leads to a power
source according to local electrical codes. Pin
3 on the input power connection is the system
interlock. Pin 3 must have line voltage applied to
satisfy the system interlock. See Manual 3A3657
for information on each pin and for interlock
requirements.
3.
Connect the Power Supply Cable from Port R
on the applicator to the power connector on
the Electrostatic Controller. This connection
should already be made at the factory for Pxxxxx
systems.
Connect
Connect
Connect Power
Power
Power Supply
Supply
Supply
The power supply is installed at the factory on the
bottom of the Air Controller. Connect the power
cord (35) to the power supply connector (16). The
supplied power cord has a NEMA 5–15P plug to
connect to AC power.
3A4232D