Connections
1. Connect the ground wire to the ground
connection (GG). Connect the other end to a true
earth ground. This connection is required for all
installations.
2. Connect the supplied controller input power cord
to the input power connection (DD) and secure
with the connector screw. This connection is
required for all installations.
The controller can operate at 100–240 VAC
(50–60 Hz). Connect the leads to a power
source according to local electrical codes. Pin
3 on the input power connection is the system
interlock. Pin 3 must have line voltage applied to
satisfy the system interlock. When the system
interlock pin is connected to line voltage, the
icon will appear on the controller. See
.
3. Connect the 7-pin end of the power cable to the
applicator power cable connection (FF) on the
controller. Connect the 4–pin end of the power
cable to the rotary applicator. Follow instructions
in the rotary applicator manual. This connection
is required for all installations.
Controller Input Power Connection
Pin No.
Function
Wire Marking
1
Neutral conductor power supply
1
2
Phase (100-240 VAC)
2
3
System Interlock ON/OFF
(100-240 VAC) = ON
3
Controller
Power Cord
PE
Grounding PE
Green/Yellow
Pre-wired Power Cable Connection
Controller
Applicator
Connector (F)
Cable
Cable
Power Supply Connector
Electrical Schematic for this cable:
18
3A3657C