![Graco Optimiser 02017 Instructions Manual Download Page 5](http://html1.mh-extra.com/html/graco/optimiser-02017/optimiser-02017_instructions-manual_2252286005.webp)
308–293 5
Selection Charts
CHART 1: GUN ASSEMBLIES, Series B (continued)
Optional Non-HVLP Compliant Gun Assemblies
With standard needle and nozzle and optional high pressure air cap
Includes:
Optional
Complete
Gun Assy.
Part No.
Needle
Assy.
P/N
*
Nozzle
P/N
{
High
Pressure
Air Cap
P/N
Orifice Size
Material Usage
(See TERMS on page 4)
236–023
238–217
276–293
189–755
0.042” (1.067 mm)
Light to Medium Fluids or Low Fluid Flow
[5–8 oz./min. (0.15–0.24 l/min.)]
236–024
238–218
276–294
189–755
0.055” (1.397 mm)
Light to Medium Fluids or Medium Fluid
Flow [6–12 oz./min. (0.18–0.36 l/min.)]
*
Maximum recommended torque to install molded fluid nozzle in the spray gun is 35 in-lbs (4 N
S
m).
{
See atomizing air pressure chart on page 7.
CHART 2: NEEDLE/NOZZLE/AIR CAP KITS
Standard Needle/Nozzle/Air Cap Kits
Standard
Includes:
Standard
Needle/
Nozzle/Air
Cap Kit
Part No.
{
Needle
Assy.
P/N
*
Nozzle
P/N
Air Cap
P/N
Orifice Size
238–233
238–217
276–293
188–754
0.042” (1.067 mm)
238–234
238–218
276–294
188–754
0.055” (1.397 mm)
238–235
238–219
276–295
188–755
0.070” (1.778 mm)
238–236
238–220
276–296
188–756
0.086” (2.184 mm)
{
See page 6 for needle assembly replacement tips.
Optional Needle/Nozzle/Air Cap Kits – available as “Build to Order”
Optional
Needle/
Includes:
Needle/
Nozzle/Air
Cap Kit
Part No.
{
Needle
Assy.
P/N
*
Nozzle
P/N
Air Cap
P/N
Orifice Size
235–306
238–703
276–290
188–754
0.020” (0.508 mm)
235–307
238–703
276–291
188–754
0.026” (0.660 mm)
235–308
238–703
276–292
188–754
0.030” (0.762 mm)
*
Maximum recommended torque to install molded fluid nozzle in the spray gun is 35 in-lbs (4 N
S
m).
{
See page 6 for needle assembly replacement tips.
Summary of Contents for Optimiser 02017
Page 19: ...308 293 19 Notes...
Page 29: ...308 293 29 Notes...
Page 30: ...30 308 293 Notes...
Page 31: ...308 293 31 Notes...