background image

INJECTION HAZARD

Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause
extremely serious injury, including the need for amputation.  Fluid splashed into the eyes or onto the
skin can also cause serious injury.

Fluid injected into the skin might look like just a cut, but it is a serious injury.  Get immediate
medical attention.

Do not point the gun at anyone or at any part of the body.

Do not put your hand or fingers over the spray tip.

Do not stop or deflect leaks with your hand, body, glove or rag.

Do not “blow back” fluid; this is not an air spray system.

Always have the tip guard and the trigger guard on the gun when spraying.

Check the gun diffuser operation weekly.  Refer to the gun manual.

Be sure the gun trigger safety operates before spraying.

Lock the gun trigger safety when you stop spraying.

Follow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve
pressure; stop spraying; clean, check, or service the equipment; and install or clean the spray tip.

Tighten all fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily.  Replace worn or damaged parts immediately.  Do
not repair high pressure couplings; you must replace the entire hose.

Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by
kinks or bends near the couplings.

WARNING

WARNING

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed into the eyes or onto the
skin, inhaled, or swallowed.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container.  Dispose of hazardous fluid according to all local,
state, and national guidelines.

Always wear protective eyewear, gloves, clothing, and a respirator as recommended by the fluid
and solvent manufacturer. 

Summary of Contents for Monark 236-065

Page 1: ...Pa 185 bar Maximum Fluid Working Pressure 180 psi 1 25 MPa 12 5 bar Maximum Air Inlet Pressure Part No 236 065 Wall Mount Pump With Fluid Regulator Part No 236 898 Wall Mount Pump Without Fluid Regula...

Page 2: ...er or modify this equipment Use only genuine Graco parts and accessories Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum working pressure of the low...

Page 3: ...when you stop spraying Follow the Pressure Relief Procedure on page 8 whenever you are instructed to relieve pressure stop spraying clean check or service the equipment and install or clean the spray...

Page 4: ...m solvents or the fluid being sprayed Keep the spray area free of debris including solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot...

Page 5: ...ground 2 Air hoses use only electrically conductive air hoses 3 Fluid hoses use only electrically conductive fluid hoses 4 Air compressor follow manufacturer s recommen dations 5 Spray gun grounding...

Page 6: ...he gun to relieve pressure may not be sufficient Install an air line filter E in the main air line to re move harmful dirt and moisture from the compressed air supply To provide automatic lubrication...

Page 7: ...d Filter L Gun Fluid Supply Hose M Gun Air Supply Hose N Air Assisted Airless Spray Gun P Air Line Lubricator R Fluid Pressure Regulator S Fluid Intake Elbow Y Ground Wire required see page 5 for inst...

Page 8: ...lush the Pump Before Using Pumps are tested with lightweight oil which is left in to protect the pump parts To prevent contamination of the fluid flush the pump with a compatible solvent before using...

Page 9: ...co Throat Seal Liquid TSL to help prolong the packing life Check the tightness of the packing nut weekly The packing nut should be tight enough to prevent leakage no tighter Always relieve the pressur...

Page 10: ...hout Fluid Regulator Includes items 1 28 43 50 02802A 1 See Detail at left 1 2 5 6 7 8 9 10 11 12 13 13 REF 14 15 16 17 18 19 39 REF 20 21 22 23 24 25 26 29 30 31 32 33 34 35 36 25 38 39 47 43 1 1 44...

Page 11: ...psm f swivel 1 18 166 999 ELBOW street reducing 1 2 npt m x 1 4 npt f 1 19 162 453 NIPPLE 1 4 npt x 1 4 npsm 1 20 236 076 HOSE suction fluid nylon 3 4 npt mbe 3 4 19 mm ID 6 ft 1 82 m long 1 21 188 86...

Page 12: ...900 Pail Mounted Pump without Fluid Regulator Includes items 1 28 33 40 50 2 8 9 Apply thread sealant to male threads except at swivel connections 1 5 6 7 10 12 13 REF 13 14 16 18 19 21 23 24 25 27 28...

Page 13: ...ducing 1 2 npt m x 1 4 npt f 1 19 162 453 NIPPLE 1 4 npt x 1 4 npsm 1 21 188 984 TUBE suction 3 4 npt m stainless steel 1 23 188 978 PLATE pump mounting stainless steel 1 24 110 271 NUT cap 3 8 16 sta...

Page 14: ...14 308 332 Notes...

Page 15: ...Pump See manual 308 106 Wetted parts Fluid Hose Nylon Wetted parts Fluid Filter See manual 307 273 Wetted parts Suction Hose and Tube Nylon 304 Stainless Steel Wetted parts Fluid Fittings 304 and 316...

Page 16: ...tal or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought...