Installation
4
3A2334A
Installation
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1.
Disconnect power source.
2.
Loosen outlet fitting or alternate outlet until no more
lubricant or air leaks from the fitting. (F
. 1)
Pump Adjustment
The pump output is adjustable using the 1-1/2 inch
(28.58 mm) hex nut (a) on the top of the pump. Adjusting
the hex nut changes the inlet port position in relation to
the piston top, which regulates g the discharge
volume.
To adjust the pump output:
1.
Follow
, page 4.
2.
Loosen screw (8k) (F
. 2).
3.
Turn hex nut (a) (F
. 2):
•
Clockwise to increase output
•
Counterclockwise to decrease output
NOTE:
Do NOT exceed 0.484 inch (12.24 mm) to pre-
vent insufficient thread engagement of the cylinder and
piston assembly.
4.
When the desired output volume is attained,
re-tighten the screw (8k), and torque the screw (8k)
to 20 in/lbs.
5.
Re tighten the outlet fitting or the alternate outlet
plug.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.
F
IG
. 1
Lube Outlet
Alternate
Outlet
(Plugged) or
Gauge Port
F
IG
. 2
0.484 in. (12.24 mm) MIN OUTPUT
0.250 in. (6.35 mm) MAX OUTPUT