6
309226
Pressure Relief
Procedure
WARNING
To help prevent injection injuries, follow
this procedure when you stop spraying
and before you service or clean the
sprayer, remove parts, or repair leaks.
psi/MPa/bar
1.
Turn Power switch (B) to OFF, and unplug sprayer.
B
9565A
2.
Turn Spray–Prime/Drain valve (J) to PRIME/
DRAIN to relieve pressure. Trigger gun to relieve
pressure that might be in hose.
J
9565A
3.
Put trigger safety (S) in SAFETY ON position.
SG2 / SG3
SG1–EF
S
S
NOTE:
Leave Spray–Prime/Drain
valve in the PRIME/DRAIN position
until you are ready to spray again.
9565A
If you suspect that the spray tip or hose is completely
clogged or that pressure has not been fully relieved
after following the steps above
, VERY SLOWLY loos-
en the tip guard retaining nut or hose end coupling to
relieve pressure gradually. Then loosen it completely.
Then clear the tip or hose obstruction.
Grounding and
Electrical Requirements
WARNING
This sprayer requires a 120V AC, 60 Hz, 15A
circuit with a grounding receptacle. Never use
an outlet that is not grounded. Do not use the
sprayer if the electrical cord has a damaged ground
prong. Use only an extension cord with an
undamaged, 3-prong plug.
Recommended extension cords for use with this
sprayer are
D
25 ft (7.6 m) 18 AWG
D
50 ft (15.2 m) 16 AWG
D
100 ft (30.5 m) 14 AWG
D
150 ft (45.7 m) 12 AWG
NOTE:
Smaller-gauge or longer extension cords may
reduce sprayer performance.