Cleanup
3A3240C
17
8.
Turn Prime/Spray valve down to
PRIME position.
9.
Turn ON/OFF switch to
ON
position.
10. Flush until approximately 1/3 of the
flushing fluid is emptied from the pail.
11. Turn ON/OFF switch to
OFF
position.
NOTE:
Step 12 is for returning paint in hose
to paint pail. One 50 ft (15 m) hose holds
approximately 1 quart (1 liter) of paint.
12. To recover paint in hose, point gun into
paint pail while holding gun firmly to the
pail.
a.
Disengage trigger lock.
b.
Pull and hold gun trigger.
c.
Turn Prime/Spray valve horizontal
to SPRAY position.
d.
Turn ON/OFF switch to
ON
position.
e.
Continue to hold gun trigger until
you see paint diluted with flushing
fluid starting to come out of gun.
13. While continuing to trigger gun, quickly
move gun to redirect spray into waste
pail. Continue triggering gun into waste
pail until flushing fluid dispensed from
gun is relatively clear.
14. Turn pressure control knob to the low-
est setting.
15. Stop triggering gun. Engage the trigger
lock.
16. Turn Prime/Spray valve down to
PRIME position.
17. Turn ON/OFF switch to
OFF
position.
18. Clean filter. See
19. Fill unit with Pump Armor
™
fluid. See
ti27120a
ti27148a
A
B
C
D
ti27151a
ti25196b