3000 PSI (207 bar) MAXIMUM WORKING PRESSURE
240 Volt, 1 or 3 Phase, 50/60 Hertz

Delivery
7.5 lb/min at 48°F temperature rise
(3.88 Kg/min at 27°C temperature rise)

Power Requirements
Electrical:

240 Volt Maximum
208 Volt Minimum
Single phase:

 

  37 Amps with 315’ (91.4m) 
  hose
Three phase:
  27 Amps with 315’ (91.4m) 
  hose

Compressed Air:

80-120 psi
(5.6-8.3 bar)
30 CFM (0.84 m³/min)

Model 973-005 includes:

Heater and heated hose controls

President plural component pump

Pump stand

50’ (15m) 3/8” ID heated hose

15’ (4.6m) 1/4” ID heated whip hose

(2) 1:1 55 gallon feed pumps

(1) Helix agitator

WARNING

Reactive Chemical Hazard

Graco Inc. does not manufacture or supply any of the reactive chemical materials that may be used in this
equipment and is not responsible for their effects.  Because of the vast number of chemicals that could be
used and their varying chemical reactions, before using this equipment, the buyer and the user should
determine all facts relating to the materials used, including any of the potential hazards involved.
Particular inquiry and investigation should be made into potential dangers relating to toxic fumes, fires,
explosions, reaction times, and exposure of human beings to the individual components or their resultant
mixtures.  Graco assumes no responsibility for loss, damage, expense or claims for bodily injury or
property damage, direct or consequential, arising from the use of such chemical components.

This manual contains IMPORTANT

WARNINGS and INSTRUCTIONS

READ AND RETAIN FOR REFERENCE

Summary of Contents for LINE X LX2000

Page 1: ...eactive Chemical Hazard Graco Inc does not manufacture or supply any of the reactive chemical materials that may be used in this equipment and is not responsible for their effects Because of the vast...

Page 2: ...is essential for optimum equipment performance This manual also contains instructions for installing and using several recommended accessories If any recommended accessory is not used just move on to...

Page 3: ...ces Be sure all gun safety devices are operating properly before each use Do not remove or modify any part of the gun this can cause a malfunction and result in serious bodily injury Safety Latch When...

Page 4: ...and solvent manufacturer s literature before using them in this sprayer HOSE SAFETY The operating and safety features of the heater used in this system are designed to be used in this system are desig...

Page 5: ...s the heater is positively grounded and therefore would not sense a fault in the heat tape which could result in static sparking 5 Air compressor or hydraulic power supply follow manufacturer s recomm...

Page 6: ...Pump 102Heated Hose 8 Air Regulator or Air Valve 103Heated Whip Hose 9 Air Dryer 201 Pump Stand 10 Air Dryer Ring 202 Y Line Strainer 11 Air Hose Feed Pump Kit 204 Fluid Hose Disp Pump 13 Main Air Sup...

Page 7: ...gulator and pin fitting 4 Mount the Air Dryer 9 in a suitable location near the ISO and RES drums See the Typical Installation on page 5 Refer to the mounting hole diagram in manual 307 548 WARNING Ne...

Page 8: ...se a Slide the male end of the sleeve A over the hose B b Grease the barbed end of the stud C and push it into the hose until it seats properly c Tighten the sleeve onto the fitting until the sleeve b...

Page 9: ...Check the continuity of the whip hose between the two outer prongs and the outer and middle prongs of the exposed connector as instructed in steps 5a and 5b The resistance between the outer prongs sh...

Page 10: ...y with VDC 0100 To ground the pumps and sprayer a Loosen the grounding lug locknut 55 and washer 52 located on the proportioning pump motor 48 Insert one end of a 12 ga 1 5 mm minimum ground wire 53 i...

Page 11: ...shut off valve 1 Refer to the Typical Installation g Adjust the Air Dryer 9 See Figure 8 Be sure the heater and heated hose circuit breakers 63 are shut off to reduce the risk of electric shock WARNIN...

Page 12: ...NOTE A minimum pressure of 1 PSI 0 07 bar is needed to open the check valves 67 h Open the feed pump air valves 8 Refer to the Typical Installation NOTE Do not reuse the purged material in both waste...

Page 13: ...adjusting any part of the system or any component to reduce the risk of serious bodily injury including fluid injection splashing in the eyes or on the skin or injury from moving parts or electric sh...

Page 14: ...ages 10 through 12 for priming procedure NOTE The first time you operate the sprayer follow these instructions carefully Then as you become familiar with this equipment you will learn how to quickly a...

Page 15: ...l for each system component for routine maintenance and repair procedures ATC SETTING AMBIENT TEMP OFF MIN MED MAX 60 F 115 F 120 F 125 F 135 F 15 C 46 C 49 C 52 C 57 C 80 F 115 F 115 F 115 F 115 F 15...

Page 16: ...15 684 027 NOTES...

Page 17: ...684 027 16 PARTS DRAWING Detail A Air Manifold Connections...

Page 18: ...217 100 081 BUSHING pipe 1 2 npt f to 3 8 npt f 1 218 214 652 HOSE air cpld 3 8 npt mbe x 1 5 457 mm long 1 REF PART NO NO DESCRIPTION QTY 219 208 851SP PUMP President Plural Component see 306 989 fo...

Page 19: ...tioning pumps The Feed Pump Kit includes an Air Dryer 217 394 two feed hoses three air hoses and related fittings See manual 307 552 ISO PUMP OIL Helps protect displacement pump throat packings 217 37...

Page 20: ...ny defective parts The equipment will be returned to the original purchaser transportation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will b...