Meter Setup and Operation Instructions
10
3A1451C
•
Press and hold the Reset
button. The currently dis-
played total is stored. The
Units of Measurement
Menu displays.
Units of Measurement
(F
Sets unit of measurement to quarts, gallons, pints, or
liters.
1.
If the Units of Measurement Menu is not already dis-
played, complete steps 1 - 3 of the Setup Menus
section, page 9.
2.
The currently stored unit of measurement: GAL,
QTS, PTS or LITERS blinks indicating you are on
the Units of Measurement Menu screen.
3.
To change the unit of measurement, do ONE of the
following.
a.
Press and hold Total but-
ton to display next unit of
measurement in the
sequence.
b.
When measurement unit
you want to use is dis-
played, press and hold
Reset button. Display
advances to Calibration
Menu.
OR
•
Press and hold Reset but-
ton. The currently dis-
played measurement unit
is stored. The Calibration
Menu displays.
Calibration (F
Recalibrates the meter for dispensing different fluids.
1.
If the Calibration Menu is not already displayed,
complete steps 1 - 4 of the Setup Menus section,
page 9.
2.
CAL blinks indicating you are on the Calibration
Menu screen. Do ONE of the following.
Use the current calibration.
•
Press and hold Reset but-
ton to lock in amount. Dis-
play returns to the
Standard Mode.
OR
Recalibrate meter as follows:
a. If the unit of measurement is gallons, pints,
or quarts, dispense exactly one quart of fluid
into a calibrated 1–quart container.
If the unit of measurement is liters, dispense
exactly one liter of fluid into a calibrated
1–liter container.
For proper calibration, you must dis-
pense the exact amount.