Operation
334627K
11
Operation
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1.
Depressurize the hotmelt system.
2.
Close the bleed-type master air valve.
3.
Actuate the applicator repeatedly until no fluid flows.
4.
If you suspect the module nozzle is clogged, remove
the nozzle and then actuate the module to relieve
pressure.
5.
If you suspect the module or fluid hose is clogged or
that pressure has not been fully relieved after
following the steps above, very slowly loosen the
inlet fitting, inlet filter, or hose end coupling to relive
pressure gradually, then loosen completely. Clear
the hose or module obstruction.
6.
Turn off air pressure to the solenoid valve.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection and splashing
fluid, follow the Pressure Relief Procedure when you
stop spraying and before cleaning, checking, or
servicing the equipment.
Summary of Contents for InvisiPac GM100 Plug-Free
Page 25: ...Repair 334627K 25 Notes ...