Installation
3A8637B
17
3.
Remove the shipping piece (or adapter connector)
and the end block (6) from the tie rods (8) of the
assembled color change stack.
4.
Separate the tie rods (8) from the color change
stack (do not separate individual color change
valves) and attach them to the holes straddling the
inlet port on the base of the meter.
5.
Slide the color change stack on the tie rods (8) and
insert the fluid output port of the color change stack
into the inlet port of the meter.
6.
Attach the end block (6) to the ends of the tie rods
(8) and secure with the two screws (9). Torque to 35
in-lbs (4.0 N•m).
Attach a Meter to a Switch Block
NOTE:
This procedure requires model FX250XK (see
on page 5) or separate IniFlex
links. This procedure describes how connect the inlet
port of an IniFlex meter to the outlet port of an IniFlex
switch block.
1.
Lubricate an o-ring and insert it in the inlet port in
the base of the meter.
2.
Align the two holes of the T-shaped spacer with the
holes straddling the inlet port of the meter and
secure with the two screws. Torque to 35 in-lbs (4.0
N•m).
3.
Lubricate an o-ring and insert it in the outlet port in
the base of the switch block.
4.
Align the two holes of the IniFlex link with the holes
straddling the outlet port of the switch block and
secure with the two screws. Torque to 35 in-lbs (4.0
N•m).
5.
Insert the stem of the T-shaped spacer in the switch
block’s outlet port and secure with the setscrew.
Torque to 50 in-lbs (5.6 N•m).
Attach a Meter to a Regulator or a Dose/Mix
Manifold
NOTE:
This procedure requires model FX250XT (see
on page 5) or a separate
T-shaped spacer and IniFlex link. This procedure
describes how the outlet port of an IniFlex meter is
connected to the inlet port of an IniFlex regulator or
dose/mix manifold.
1.
Lubricate an o-ring and insert it in the outlet port in
the base of the meter.
2.
Align the two holes of the IniFlex link with the holes
straddling the outlet port of the meter and secure
with the two screws. Torque to 35 in-lbs (4.0 N•m).
3.
Lubricate an o-ring and insert it in the inlet port in
the base of the regulator or dose/mix manifold.
4.
Align the holes in the IniFlex link connector block
with the holes straddling the inlet port of the
regulator or dose/mix manifold, and secure with two
screws. Torque to 35 in-lbs (4.0 N•m).
5.
Insert the stem of the T-shaped spacer in the
meter’s outlet port and secure with the setscrew.
Torque to 50 in-lbs (5.6 N•m).