HOSE AND GUN CONNECTIONS
Connect one end of the fluid hose (D) to the filter outlet
nipple (11) and the other to the fluid inlet of the gun (E). Do
not install the spray tip in the gun yet. T o use a second
gun with the pump, refer to pages 11 and 12.
Close the bleed-type master air valve (17) and the air
regulator (16). Connect the main air line (B) to the 1/2
npt(f) air regulator inlet.
INSTALLING PUMP MODEL 222-268
Refer to Fig. 2.
NOTE: Apply pipe sealant to all male threads, except at
swiveling connections.
1. Mount the pump wall bracket (7) 5 ft (1.5 m) above
the floor. Be sure the wall is strong enough to support
the weight of the pump and accessories, fluid, hoses,
and stress caused during pump operation. Refer to
Mounting Dimensions on page 19 and Mounting
Bracket manual 306-783.
2. Install the gasket (2) and pump (1) on the
wall
bracket (7), aligning the two mounting holes in the
gasket and pump with those in the bracket. To secure
the pump, install the screws (6) and lockwashers
(supplied with the bracket) from below the
wall
bracket.
3. Apply pipe sealant (3) to one end of the 1/2 npt nipple
(18) and screw the nipple into the pump’s air inlet. In-
stall the air regulator (16) and bleed-type master air
valve (17) by screwing the swivel end of the union
(19) onto the nipple (18). This completes installation
of the air regulator assembly.
If you are installing a
heated system, skip steps 4 through 6 and proceed
to
Installing a Heated System on page 8.
4. Apply pipe sealant (3) and install the long 3/8 npt nip-
ple (9) in the pump’s fluid outlet. Connect the fluid fil-
ter (8) to this nipple.
5. Screw the swivel end of the suction kit (21) onto the
pump fluid intake.
6. Connect the air and fluid hoses as described at left.
GROUNDING
Before operating the pump, ground the system as ex-
plained under
FIRE OR EXPLOSION HAZARD on
page 4 and
Grounding on page 5.
WARNING
05411
Fig. 2
7
2
1
6
16
19
18
9
8
21
APPLY PIPE
SEALANT (3)
TO PUMP END ONLY
APPLY PIPE
SEALANT (3)
G
17
PART OF BRACKET (7)