19
307-930
Dimensions
05419
9.25 in. (235 mm)
BETWEEN HOLE
PATTERNS
7/16” DIA. HOLES FOR
PUMP WALL BRACKET
(MOUNT 5 ft [1.5 m]
ABOVE FLOOR;
REFER TO 306-783 FOR
INSTRUCTIONS)
M8 OR 5/16” DIA. HOLES FOR
HEATER WALL BRACKET
(OR USE BRACKET AS
TEMPLATE TO MARK WALL)
5”
(127 mm)
6”
(152 mm)
6.25”
(159 mm)
5.375”
(137 mm)
Technical Data
Maximum working pressure
3000 psi (210 bar)
. . . . . . .
Maximum incoming air pressure
100 psi (7 bar)
. . . . . . .
Ratio
30:1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid flow at 60 cpm
1.0 gpm (3.8 liters/min)
. . . . . . . . .
Air consumption
approx. 23 scfm
. . . . . . . . . . . . . . . . . . .
(0.79 m3/min) at 1.0 gpm
(3.8 liter/min) flow rate at
70 psi (4.8 bar) air pressure
Wetted parts
See separate
. . . . . . . . . . . . . . . . . . . . . . .
component instruction manuals
Sound Data*
Sound Pressure Level
94 dB(A)
. . . . . . . . . . . . . . . . . . . .
Sound Power Level
108 dB(A)
. . . . . . . . . . . . . . . . . . . . .
Weight
222–268
65 lb
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
221–123
See weight of individual
. . . . . . . . . . . . . . . . . .
components
Maximum fluid temperature
{
222–268
180
_
F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
221–123
180
_
F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
* Sound level measured at stated system conditions:
222–268 and 221–123; 100 psi air, at 60 cpm.
Sound level measured per ISO 3744–1981.
{
In most cases the hose is the limiting factor to the
temperature factor to the temperature rating. For high-
er temperature applications, contact Graco or your lo-
cal distributor for additional information.
r
Manual
Change Summary
Added sound level data to comply with
CE marking re-
quirements. Added technical data. Added temperature
ratings for 223–540 and 222–263 hoses. Added a ther-
mal expansion warning. Replaced old warnings with new
warnings. Changed manual to one color
. Replaced
scanned art with electronically drawn art. Added ground
wire assembly 237–569 to bill of materials of 222–268
and 221–123. Deleted grounding clamp 103–538 and
ground wire 208–950 from accessories. Replaced bleed-
type air valve 107–142 with bleed-type air valve 113–269.
PTFE