background image

308–507

16

THE GRACO WARRANTY

WARRANTY AND DISCLAIMERS

Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and

workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. As

purchaser’s sole remedy for breach of this warranty, Graco will, for a period of twenty four months from date of

sale, repair or replace any part of the equipment proven defective. This warranty applies only when the

equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by

faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence,

accident, tampering, or substitution of non–Graco component parts. Nor shall Graco be liable for malfunction,

damage or wear caused by the incompatibility with Graco equipment of structures, accessories, equipment or

materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of

structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective for examination

by Graco to verify the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge

any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If

inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a

reasonable charge, which charges may include the costs of parts, labor and transportation.

DISCLAIMERS AND LIMITATIONS

THE TERMS OF THIS W ARRANTY CONSTITUTE THE PURCHASER’S SOLE AND EXCLUSIVE

REMEDY AND ARE IN LIEU OF ANY OTHER W ARRANTIES (EXPRESS OR IMPLIED), INCLUDING

WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,

AND OF ANY NON–CONTRACTUAL LIABILITIES, INCLUDING PRODUCT LIABILITIES, BASED ON

NEGLIGENCE OR STRICT LIABILITY . EVER Y FORM OF LIABILITY FOR DIRECT , SPECIAL OR

CONSEQUENTIAL DAMAGES OR LOSS IS EXPRESSLY EXCLUDED AND DENIED. IN NO CASE SHALL

GRACO’S LIABILITY EXCEED THE AMOUNT OF THE PURCHASE PRICE. ANY ACTION FOR BREACH

OF WARRANTY MUST BE BROUGHT WITHIN THREE (3) YEARS OF THE DATE OF SALE.

EQUIPMENT NOT COVERED BY GRACO WARRANTY

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY

AND FITNESS FOR A P ARTICULAR PURPOSE, WITH RESPECT T O ACCESSORIES, EQUIPMENT,

MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not

manufactured by Graco (such as electric motor, switches, hose, etc.) are subject to the warranty, if any, of their

manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these

warranties.

IMPORTANT PHONE NUMBERS

TO PLACE AN ORDER

,  contact your Graco distributor , or call this number to identify the

distributor closest to you:  

1–800–328–0211 Toll Free

FOR TECHNICAL ASSIST ANCE

, service repair information or assistance regarding the

application of Graco equipment:  

1–800–543–0339 Toll Free

Factory Branches:

 Atlanta, Chicago, Dallas, Detroit, Los Angeles, West Caldwell (N.J.)

Subsidiary and Affiliate Companies:

 Canada; England; Switzerland; France; Germany; Hong Kong; Japan

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

PRINTED IN U.S.A. 308–507  5/90

Summary of Contents for Hydra-Clean 308-507

Page 1: ...ries A 900 psi 62 bar MAXIMUM WORKING PRESSURE 2 5 gpm 10 lpm MAXIMUM FLOW RATE HYDRA CLEAN 10 1 PRESIDENT CART MOUNTED P N 800 413 Series A 1800 psi 124 bar MAXIMUM WORKING PRESSURE 3 0 gpm 11 lpm MAXIMUM FLOW RATE HYDRA CLEAN 10 1 PRESIDENT PORTABLE TANK MOUNTED P N 800 295 Series A 1800 psi 124 bar MAXIMUM WORKING PRESSURE 3 0 gpm 11 lpm MAXIMUM FLOW RATE GRACO INC P O Box 1441 MINNEAPOLIS MN 5...

Page 2: ...xotic coatings injected directly into the bloodstream Consultation with a plastic surgeon or reconstructive hand surgeon may be advisable Pressure Relief Procedure To reduce the risk of serious bodily injury including fluid injection and splashing in the eyes or on the skin always follow this procedure whenever you stop spraying for more than 10 minutes when shutting down and before checking or re...

Page 3: ...age ALL FLUID HOSES MUST HA VE STRAIN RELIEFS ON BOTH ENDS The strain reliefs help protect the hose from kinks or bends at or close to the coupling which can result in hose rupture TIGHTEN all fluid connections securely before each use High pressure fluid can dislodge a loose coupling or allow high pressure spray to be emitted from the coupling NEVER use a damaged hose Before each use check entire...

Page 4: ...ater Supply CAUTION Before attaching to the water supply check your local plumbing code regarding cross connection to the water supply A backflow preventer P N 801 133 is available to prevent backflow of contaminated water into the fresh water supply Install it upstream from the pump 800 412 800 413 only CAUTION If inlet water pressure is over 60 psi 4 1 bar a regulating water valve P N 800 258 mu...

Page 5: ... The flow rate of the chemical may be regulated by turning the chemical adjustment knob on the injector Maximum chemical flow is at a full two turns counterclockwise from the closed clockwise position WARNING DO NOT attempt to open or close the adjustable nozzle when the spray gun is in use BE SURE that the trigger safety latch on the gun is in the ON position before adjusting to avoid serious bod...

Page 6: ...uce the risk of serious bodily injury including fluid injection or splashing in the eyes or onto the skin use extreme caution when changing spray tips If a spray tip clogs while spraying engage the gun safety latch immediately ALWAYS follow the procedure below 1 Follow the Pressure Relief Procedure 2 Point the gun and wand away from yourself and anyone else 3 Without holding your hand over the spr...

Page 7: ...arts always follow the Pressure Relief Procedure Warning before proceeding Interval What to do Daily Clean water inlet screen and filter Lubricate air motor if there is not automatic oiling by placing 15 drops of light machine oil in the pump air inlet Each 40 hours of operation Check that the packing nut is tight Tighten snug Overtightening will damage packings See the appropriate pump Instructio...

Page 8: ...308 507 8 PARTS DRAWING 800 412 5 1 Monark Cart Mounted Hydra Clean Pressure Washer 1 2 3 4 5 6 16 15 8 9 10 7 20 18 17 14 13 27 26 25 24 12 23 10 22 28 11 21 22 28 19 ...

Page 9: ...AND ASSEMBLY incl 22 23 24 25 26 27 28 1 13 801 683 STRAINER Chemical 1 14 803 059 TUBING Chemical 5 16 ID 8 ft 15 207 278 ACCUMULATOR see instruction manual 306 933 1 16 803 446 FITTING Swivel 1 2 X 1 2 1 17 202 156 REGULATOR ASSEMBLY see instruction manual 307 204 1 18 208 393 VALVE Ball 3 8 x 3 8 see instruction manual 307 068 1 19 802 048 TIP Spray 15 Degree 1 20 208 470 PUMP 5 1 Monark see in...

Page 10: ...308 507 10 PARTS DRAWING 800 413 10 1 President Cart Mounted Hydra Clean Pressure Washer 23 22 21 20 18 10 17 6 15 14 10 9 8 7 6 5 4 3 2 1 11 29 28 27 26 25 19 24 21 19 24 16 12 13 ...

Page 11: ... 1 12 800 396 GUN WAND ASSEMBLY incl 19 25 26 27 28 29 1 13 800 374 HOSE ASSEMBLY W QUICK COUPLERS incl 16 19 21 1 14 100 081 BUSHING Hex 3 8 X 1 2 1 15 206 842 PUMP 10 1 President see instruction manuals 306 816 306 982 1 16 801 007 HOSE High Pressure 50 ft 1 17 207 278 ACCUMULATOR see instruction manual 306 933 1 18 803 473 INJECTOR Chemical 1 19 801 009 QUICK COUPLER Female 1 4 incl 24 2 20 150...

Page 12: ... 10 1 President Tank Mounted Hydra Clean Pressure Washer 13 3 7 3 3 5 2 50 41 34 27 33 1 28 32 35 36 58 59 35 37 60 61 30 47 46 42 52 38 38 40 41 52 50 52 51 48 49 44 45 43 22 23 21 20 19 18 17 16 29 30 31 15 14 26 3 6 8 9 10 11 12 62 ...

Page 13: ... 3 8 see instruction manual 307 068 1 29 100 023 WASHER Flat 5 16 10 30 100 214 WASHER Lock 5 16 18 31 801 941 SCREW Cap hex hd 5 16 18 X 1 10 REF PART NO NO DESCRIPTION QTY 32 100 081 BUSHING Hex 3 8 X 1 2 1 33 801 795 BUSHING Hex 1 2 X 3 4 1 34 155 699 ELBOW Street 3 8 X 90 1 35 801 123 CLAMP Hose 2 36 803 110 BRACKET Pump Support 1 37 801 788 HOSE BARB 3 4 X 1 2 1 38 801 957 SLEEVE 18 1 39 801 ...

Page 14: ... 100 Lbs Air Pressure Air Consumption At 70 Lbs Air Pressure Air Consumption At 40 Lbs Air Pressure LEGEND 0 5 10 15 20 5 1 MONARK PUMP DELIVERY PSI GPM CFM 0 5 10 15 20 25 20 15 10 5 0 0 4 0 3 0 2 0 1 0 16 14 12 10 8 6 4 2 0 BAR Pumps may be operated continuously to shaded area f MIN M3 MIN PUMP OUTLET PRESSURE AIR CONSUMPTION Outlet Pressure At 100 Lbs Air Pressure Outlet Pressure At 70 Lbs Air ...

Page 15: ...ngs Acrylonitrile and Buna N cover and tube Anodized aluminum Aluminum or bronze alloys Brass Copper Nylon composite Viton Buna N Cotton phenolic 303 304 and 316 Stainless steel Polymide 12 thermoplastic Carbon steel Zinc with or without yellow chromate plate and Viton are tradenames of the DuPont Company ACCESSORIES Must be purchased separately Air Line Filter 106 149 1 2 npt inlet and outlet 250...

Page 16: ... be made at a reasonable charge which charges may include the costs of parts labor and transportation DISCLAIMERS AND LIMITATIONS THE TERMS OF THIS W ARRANTY CONSTITUTE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY AND ARE IN LIEU OF ANY OTHER W ARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF ANY NON CONTRACTUAL LIABILITIES INCL...