WARNING

PRESSURIZED EQUIPMENT HAZARD

Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin
and cause serious injury.

D

Do not stop or deflect fluid leaks with your hand, body, glove, or rag.

D

Follow the 

Pressure Relief Procedure

 on page 6 whenever you: are instructed to relieve the

pressure; stop spraying; clean, check, or service the equipment; and install or clean the fluid
nozzle.

D

Tighten all the fluid connections before operating the equipment.

D

Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.
Permanently coupled hoses cannot be repaired; replace the entire hose.

FIRE AND EXPLOSION HAZARD

Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and
result in fire or explosion and serious injury.

D

Ground the equipment and the object being sprayed. See 

Grounding 

on page 5.

D

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvent or the fluid being
sprayed.

D

Extinguish all the open flames or pilot lights in the spray area.

D

Electrically disconnect all the equipment in the spray area.

D

Keep the spray area free of debris, including solvent, rags, and gasoline.

D

Do not turn on or off any light switch in the spray area while operating or if fumes are present.

D

Do not smoke in the spray area.

D

Do not operate a gasoline engine in the spray area.

D

If there is any static sparking while using the equipment, 

stop spraying immediately

. Identify and

correct the problem.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed.

D

Know the specific hazards of the fluid you are using.

D

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.

D

Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and
solvent manufacturer.

D

Graco does not manufacture or supply the reactive chemical components that may be used in this
equipment and is not responsible for injury or property loss, damage, expense, or claims (direct or
consequential) that arise from the use of such chemical components.

Summary of Contents for Hydra-Cat A Series

Page 1: ...p 600 psi 4 0 MPa 40 bar Maximum Working Pressure Part No 207914 Series E 1 1 Mix Ratio by Volume Includes Model 215932 Displacement Pump Part No 903843 Series A 1 1 Mix Ratio by Volume Includes Model 904287 Displacement Pump This model is certified and approved 307001N 01328 Important Safety Instructions Read all warnings and instructions in this manual Save these instructions Parts ...

Page 2: ...odify this equipment Use only genuine Graco parts and accessories D Check the equipment daily Repair or replace worn or damaged parts immediately D Do not exceed the maximum working pressure of the lowest rated system component This equip ment has a 600 psi 4 0 MPa 40 bar maximum working pressure D Do not lift pressurized equipment D Route the hoses away from the traffic areas sharp edges moving p...

Page 3: ...yed D Extinguish all the open flames or pilot lights in the spray area D Electrically disconnect all the equipment in the spray area D Keep the spray area free of debris including solvent rags and gasoline D Do not turn on or off any light switch in the spray area while operating or if fumes are present D Do not smoke in the spray area D Do not operate a gasoline engine in the spray area D If ther...

Page 4: ...4 307001 Notes ...

Page 5: ... reduce the risk of static sparking ground the spray er and all other spray equipment used or located in the spray area Check your local electrical code for de tailed grounding instructions for your area and type of equipment Ground all of this spray equipment D Pump use a ground wire and clamp to connect the sprayer to a true earth ground See Fig 1 D Feed pumps use a ground wire and clamp to conn...

Page 6: ...e risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 6 The displacement pump was factory tested in light oil which was left in to protect the pump parts To prevent contamination of the fluid being pumped flush the pump before using it Be sure the solvent used is compatible with the fluid being pumped Place each pump intake int...

Page 7: ... always follow the Pressure Relief Procedure on page 6 Keep the wet cups packing nuts 1 3 filled with ISO Pump Oil and check the tightness of the packing nut weekly The packing nut should be tight enough to prevent leakage no tighter Too tight an adjustment will cause the packings to bind or wear prematurely and leak Always relieve the pressure before adjust ing the packing nut Never allow the sup...

Page 8: ...an service See manual 307430 Pump runs but RES output low on both strokes Dirty worn or damaged RES pump intake valve Clean service See manual 307430 Empty or inadequate fluid supply Refill or change container Pump runs but ISO output low on upstroke Dirty worn or damaged ISO pump piston valve Service See manual 307430 p Worn or damaged ISO pump piston pack ings Service See manual 307430 Pump runs...

Page 9: ...he displacement rods and secure with the cotter pins 9 Secure the rod extensions to the yoke 18 with the lockwashers 5 and nuts 7 3 Position the tie rods 19 in the tie plate 16 and install the nuts 8 torquing evenly to 30 50 ft lb 47 68 NSm 4 Screw the shouldered nut 15 down onto the yoke 5 Reconnect the ground wire if it was disconnected during service Mixing Antifreeze and Water To ensure comple...

Page 10: ...81 NUT hex jam 5 8 in 11 2 8 101712 NUT lock 5 8 in 11 4 9 101946 PIN cotter SST 0 125 in 3 2 mm dia 1 50 in 38 1 mm lg 3 10 156082 O RING Model 903843 only 2 14 168418 PLATE adapter 1 15 168453 NUT shouldered 1 16 168600 PLATE tie 1 17 168606 ROD connecting 1 18 168607 YOKE connecting 1 19 171313 ROD tie 10 687 in 272 mm 4 20 171314 EXTENSION displacement rod 2 21 207352 AIR MOTOR See manual 3069...

Page 11: ...aximum Recommended Pump Speed 60 cycles min 6 gpm 22 8 liters min Recommended Speed for Optimum Pump Life 20 40 cpm Wetted Parts Stainless Steel nitralloy steel Buna n PTFE Mounting Hole Layout Dimensions 7225A 4 75 in 121mm Square Cutout Four 0 438 in 11 1 mm Holes on 5 5 in 140 mm Bolt Circle 7224A 6 375 in 162 mm 1 2 npt f Fluid Outlet 3 4 npt f 1 in npt m 1 1 2 in npt m or 3 4 npt m Fluid Inle...

Page 12: ...ove The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco makes no warranty and disclaims all implied warranties of merchantability an...

Reviews: