background image

To Inspect or Replace Drive Spline or Mixing Shaft

If mixer motor runs but material is not mixed properly:

Use a spanner wrench to unscrew the connecting hous-
ing retainer nut (23) CLOCKWISE off the air motor-it
has left hand threads. Inspect the spline shaft 

 for

wear or damage and replace if necessary. Also check
the thrust spring 

 and replace if it is weak or broken.

See Fig 4.

Screw the mixing assembly retaining nut (11) COUNT-
ERCLOCKWISE off the head 

 and remove the mix-

ing assembly. Remove the mixing shaft 

 from the

chamber 

 See Figures 5 and 6. Place parts in sol-

vent and clean thoroughly. Inspect parts for wear or
damage. Replace the entire mixing assembly if the mix-

ing chamber is nicked or scored. Check the o-ring 

 in

place on the head 

 and replace if necessary.

To inspect or replace the drive shaft 

 clean all

material off the shaft, then loosen the packing nut (19)
and pull the shaft through the back of the connecting
housing. If the shaft is damaged in any way, replace it.
Check the packing contact area for burrs or scratches

which will cause premature packing wear.

To reassemble, install one or two washers (27) between
the spline shaft and air motor to obtain a 0.347 to 0.437

in. (8.8 to 11   mm) dimension. Refer to Detail in Fig 4.
Leave the packing nut (19) loose until the mixer is

assembled, then tighten.

Replace Packings
If material leaks around the packing retainer 

 and

tightening the packing nut 

 does not stop it:

   

(8.8 to 11.1 

Disassemble the mixer as explained above. Turn the
packing nut all the way up against the housing retaining
nut 

 Remove the packing retainer 

 See Fig 5.

Remove the packings carefully, using a suitable hooked

tool. Be careful not to scratch the housing 

 Inspect

the packing retainer gland end. If it is damaged, replace
the retainer.

Insert a new male gland 

 into the housing, then in-

stall new packings 

 one at a time, pushing each all

the way into the housing. Install the packing retainer in
the housing 

 Reassemble the mixer, then tighten

the packing nut (19) snugly, just enough to stop

leakage.

4 2 ’

Fig 5

 

Summary of Contents for Hydra-Cat 207-388 F

Page 1: ...Parts ...

Page 2: ...ffuser If your gun is equipped with one The diffuser breaks up spray and reduces the risk of injection when the tip is not installed Check diffuser operation regular ly Follow the Pressure Relief Procedure below then remove the spray tip Aim the gun into a metal pail holding the gun firmly to the pail Using the lowest possible pressure trigger the gun If the fluid emitted is not diffused into an i...

Page 3: ...E SAFETY y_ y y K High pressure fluid in the hoses can be very dangerous If the hose develops a pinhole leak split or rupture due to any kind of wear damage or misuse the high pressure spray emitted from it can cause an injection injury or other serious bodily in jury or property damage ALL FLUID HOSES MUST HAVE SPRING GUA RDSI The spring guards help protect the hose from kinks or bends at or clos...

Page 4: ... outlet start the mixer motor and open the solvent valve When clean solvent comes form the outlet close and the sol vent valve then stop the mixer motor Let all samples cure or harden completely Examine each one for proper cure Select the sample which cured properly at the lowest air pressure and use that pressure for the mixer air supply Repeat the test if none of the samples cured properly CAUTI...

Page 5: ...ensing for a short time close the mixer material valves and open the solvent flush valve Leave the motor running Point the material outlet into a waste container open the dispensing valve and flush until the solvent is clean Close the solvent valve stop the motor and open the dispensing valve to relieve pressure For longer shutdowns solvent flush as above follow the Pressure Relief Procedure on pa...

Page 6: ...sed or clogged air valves 42 or lines Check Requires 25 to 30 CFM at 106 psi 7 bar for con tinuous operation Open clear Hardened material in mixing chamber Material supply container empty Plugged material inlet or check valve See last section of Service page 7 Observe pot life Refill prime system Clean Refer to Service Air motor 7 malfunction Replace Refill prime system Clean refer to Service Not ...

Page 7: ...sing If the shaft is damaged in any way replace it Check the packing contact area for burrs or scratches which will cause premature packing wear To reassemble install one or two washers 27 between the spline shaft and air motor to obtain a 0 347 to 0 437 in 8 8 to 11 l mm dimension Refer to Detail in Fig 4 Leave the packing nut 19 loose until the mixer is assembled then tighten Replace Packings If...

Page 8: ...mmer to break it loose then pry it off Knock out the mixing shaft if possible and place parts in a pail of compatible solvent If the mixing shaft 204 will not come out and there is no solvent available that will dissolve the material without damaging the parts install a complete new mixing assembly Refer to mixing assembly Completely disassemble the mixer and clean it thoroughly Reassemble using n...

Page 9: ...NER packing female gland V PACKING PTFE SHAFT mixer drive NUT plain round l l 8 12 UNF 2 thd size packing nut GUIDE spring check valve BRACKET mounting GLAND packing male QTY 3 2 3 2 2 1 2 1 1 2 i r 1 1 1 REF PART DESCRIPTION NO NO 167 765 167 766 167 770 168492 170 786 178 747 217561 207 411 213 040 Series B 104893 104892 164 900 178 746 165 274 165 964 178 745 172 094 178 743 165 599 208390 167 ...

Page 10: ...Model 207 390 GASKET copper MIXING SHAFT 2 blade Model 267 389 MIXING SHAFT 3 blade Model 207 390 BEARING end thrust 2 0 5 207494 Model 207 389 Model 207 390 204 BALL VALVE KIT 218 412 Adapts Series E and older power mixers to new style ball valve and actuating lever style If your mixer is Series E or older the material ball valves must be replac ed together and a new lever installed as the old pa...

Page 11: ......

Page 12: ...t substitution of non Grace parts faulty installation or tampering This warranty is conditioned upon the prepaid return of the equipment claimed to be defective for examination by Grace to verify the claimed defect If the claimed defect is verified Grace will repair or replace free of charge any defective parts The equipment will be returned to the original purchaser transportation prepaid If insp...

Reviews: