Performance Charts
26
3A6938D
NOTE:
See
on page 3 for your pump part number.
XL 3400 Air Motor, 1500cc Lower (Jx45xx)
FLUID PR
ESSUR
E
FLUID FLOW IN GPM (LPM)
AIR FLOW
psi (MPa, bar)
500 (3.5, 35)
400 (2.8, 28)
300 (2.1, 21)
200 (1.4, 14)
100 (0.7, 7)
0
2.0
(7.0)
4.0
(15.0)
6.0
(22.5)
8.0
(30.0)
10.0
(37.9)
12.0
(45.4)
14.0
(53.0)
0
80 (2.24)
60 (1.68)
40 (1.12)
20 (0.56)
SCFM (m
3
/min.)
0 (0.0)
B
A
C
B
A
C
70 (1.96)
50 (1.4)
30 (0.84)
10 (0.28)
450 (3.1, 31)
350 (2.4, 24)
250 (1.7, 17)
150 (1.0, 10)
50 (0.3, 3)
XL 3400 Air Motor, 2000cc Lower (Jx35xx)
FLUID PR
ESSUR
E
FLUID FLOW IN GPM (LPM)
AIR FLOW
psi (MPa, bar)
300 (2.1, 21)
200 (1.4, 14)
100 (0.7, 7)
0
2.0
(7.0)
4.0
(15.0)
6.0
(22.5)
8.0
(30.0)
10.0
(37.9)
12.0
(45.4)
14.0
(53.0)
0
60 (1.68)
40 (1.12)
20 (0.56)
0
B
A
C
B
A
C
50 (1.4)
30 (0.84)
10 (0.28)
350 (2.4, 24)
250 (1.7, 17)
150 (1.0, 10)
50 (0.3, 3)
SCFM (m
3
/min.)
0
4
8
11
14
17
21
24
CYCLES PER MIN.
0
5
10
15
20
24
28
32
CYCLES PER MIN.
Key:
A
100 psi (0.7 MPa, 7.0 bar) air pressure
B
70 psi (0.49 MPa, 4.9 bar) air pressure
C
40 psi (0.28 MPa, 2.8 bar) air pressure
The shaded area within the table shows the recommended
range for continuous duty circulation applications.
Fluid outlet pressure
Air consumption
XL 3400 Air Motor, 750cc Lower (Jx90xx)
FLUID FLOW IN GPM (LPM)
AIR FLOW
0
1.0
(3.8)
2.0
(7.0)
3.0
(11.3)
4.0
(15.0)
5.0
(19)
6.0
(22.5)
7.0
(26.5)
0
80 (2.24)
60 (1.68)
40 (1.12)
20 (0.56)
0 (0.0)
70 (1.96)
50 (1.4)
30 (0.84)
10 (0.28)
CYCLES PER MIN.
0
5
10
15
20
24
28
32
B
A
C
B
A
C
1000 (6.9, 69)
800 (5.5, 55)
600 (4.1, 41)
400 (2.8, 28)
200 (1.4, 14)
900 (6.2, 62)
700 (4.8, 48)
500 (3.5, 35)
300 (2.1, 21)
100 (0.7, 7)
psi (MPa, bar)
SCFM (m
3
/min.)
Summary of Contents for High-Flo JS17A8
Page 15: ...Repair 3A6938D 15...