![Graco Gun Flush Box 244105 Instructions-Parts List Manual Download Page 12](http://html1.mh-extra.com/html/graco/gun-flush-box-244105/gun-flush-box-244105_instructions-parts-list-manual_2251120012.webp)
12
309227
Troubleshooting
Problem
Cause
Solution
Gun is in the Gun Flush Box, but
Air is shut off.
Turn on the air to the system.
,
the system will not purge or mix.
Gun switch is not activating.
Test the switch. Replace it if it is dam-
aged.
Operator switch is not wired properly.
Check the I/O to see if the proper
input is activating. Rewire the switch
if necessary.
Tubing is not installed correctly.
Check tubing against schematic on
page 9.
Gun Flush Box fails to purge after
the pot life time ends.
Gun is not in Gun Flush Box.
Place the gun in the Gun Flush Box
when it is not in use.
p
Gun switch is not activating.
Test the switch. Replace it if it is dam-
aged.
Gun trigger is not open when the
Gun Flush Box controller acti-
Tubing is not installed correctly.
Check tubing against schematic on
page 9.
vates it.
Cylinder is damaged.
Clean cylinder rod or replace.
Gun is not properly set in the gun
holder.
Check to make sure the gun holder is
not obstructed by buildup.
Lower cylinder is out of adjustment.
Adjust the block as instructed in
Trig-
ger Height
Adjustment
procedure
on page 10.
Gun is out of the Gun Flush Box
with the door closed but the atom-
Lid switch or gun switch failure.
Check the switches and replace if
necessary.
izing air is off.
No air flow to the Gun Flush Box.
Check the air supply and tubing.