Warnings
6
3A7600C
Electric Motor Warnings
DANGER
SEVERE ELECTRIC SHOCK HAZARD
This equipment is powered by more than 240 V. Contact with this voltage will cause death or serious
injury.
•
Turn off and disconnect power cord before servicing equipment.
•
Connect only to grounded electrical outlets.
•
Use only 4-wire extension cords.
•
Ensure ground prongs are intact on power and extension cords.
•
Do not expose to rain. Store indoors.
•
All electrical wiring must be done by a qualified electrician and comply with all local codes and
regulations.
GROUNDING
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. This product is equipped with a cord
having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet
that is properly installed and grounded in accordance with all local codes and regulations.
•
Improper installation of the grounding plug is able to result in a risk of electric shock.
•
This product is for use on a nominal 480 V or 380 V circuit and has a grounding plug similar to the
plugs illustrated in the figure below.
•
Only connect the product to an outlet having the same configuration as the plug.
•
Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qual-
ified electrician.
•
Do not use an adapter with this product.
•
When repair or replacement of the cord or plug is required, only connect the grounding wire to the
extended ground blade or pin.
•
The wire with insulation having an outer surface that is green with or without yellow stripes is the
grounding wire.
•
Check with a qualified electrician or serviceman when the grounding instructions are not completely
understood, or when in doubt as to whether the product is properly grounded.
Extension Cords:
•
Use only a 4-wire extension cord that has a grounding plug and a grounding receptacle that accepts
the plug on the product.
•
Make sure your extension cord is not damaged. If an extension cord is necessary, use 10 AWG
(6.0 mm
2
) minimum to carry the current that the product draws.
•
An undersized cord results in a drop in line voltage and loss of power and overheating.
480 V
380 V
Summary of Contents for GrindLazer 25P474
Page 50: ...Parts Dashboard Battery Assemblies Gas 50 3A7600C Parts Dashboard Battery Assemblies Gas...
Page 68: ...Wiring Diagram 68 3A7600C Wiring Diagram Gas Models...
Page 69: ...Wiring Diagram 3A7600C 69 Propane Models...
Page 70: ...Wiring Diagram 70 3A7600C Electric Models 480V...
Page 71: ...Wiring Diagram 3A7600C 71 Electric Models 380V...