background image

16

GC-1393F

Dispense Tip Reference Chart

Part

Number

Orifice

LPA2-147-1525

0.015

                 1540

0.015

                 1550

0.015

                 1565

0.015

                 1825

0.018

                 1840

0.018

                 1850

0.018

                 1865

0.018

                 2125

0.021

                 2140

0.021

                 2150

0.021

                 2165

0.021

                 2325

0.023

                 2340

0.023

                 2350

0.023

                 2365

0.023

                 2625

0.026

                 2640

0.026

                 2650

0.026

                 2665

0.026

                 3125

0.031

                 3140

0.031

                 3150

0.031

                 3165

0.031

                 3625

0.036

                 3640

0.036

                 3650

0.036

                 3840

0.038

                 3850

0.038

                 4325

0.043

                 4340

0.043

                 4350

0.043

                 4365

0.043

                 5225

0.052

Part

Number

Orifice

LPA2-147-5240 

0.052

5250

0.052

5265

0.052

6240

0.062

6250

0.062

6265

0.062

 7240

0.072

  7250

0.072

7840

0.078

Note:

Use p/n: LPA2-120G and p/n: LPA2-121G

when  using  LPA2-147-XXXX  and  23047-XX 

series spray tips.

LPA2-147-XXXX.   (Requires Seal, P/N 20333-00 and Retainer, P/N 22274-00.)

Options

Summary of Contents for Glascraft Formula-X

Page 1: ...s manual Save these instructions Operation Formula X GC 1393G ENG Low emission external mix dispense gun for use with polyester resin and gel coat For professional use only Maximum fluid working press...

Page 2: ...nings 3 Important Safety Information 5 Grounding 6 Set Up 7 Parts 8 Assembly Drawings 9 Pressure Relief Procedure 12 Maintenance 13 Maintenance 14 Technical Data 17 Graco Ohio Standard Warranty 18 Gra...

Page 3: ...when in the operating area of the equipment to help protect you from serious injury including eye injury inhalation of toxic fumes burns and hearing loss This equipment includes but is not limited to...

Page 4: ...ts Cleaning Solvent Hazard Created for CEDs Texture Sprayer May have use with other waterbase application equipment with plastic parts th can be damaged by certain solvents WARNING PRESSURIZED ALUMINU...

Page 5: ...ontact with isocyanates appropriate per sonal protective equipment including chemically impermeable gloves boots aprons and goggles is also required for everyone in the work area Some materials may be...

Page 6: ...lly a film will form on the surface and the ISO will begin to gel increasing in viscosity If used this partially cured ISO will reduce performance and the life of all wetted parts To prevent exposing...

Page 7: ...id Eventually a film will form on the surface and the ISO will begin to gel increasing in viscosity If used this partially cured ISO will reduce performance and the life of all wetted parts To prevent...

Page 8: ...t Number Description 23792 00 GUN AIR KIT 23793 00 GUN SEAL KIT 23732 00 GUN FLUID VALVE KIT Standard Equipment Part Number Description 23750 01 FORMULA X DISPENSE GUN GC 1393 USER MANUAL Formula X Di...

Page 9: ...9 GC 1393F 23750 01 Formula X Dispense Gun Assembly Drawings...

Page 10: ...10 GC 1393F 23750 01 Formula X Dispense Gun Assembly Drawings 189018...

Page 11: ...4 00 TRIGGER STOP CAP 1 23775 01 GEAR 2 23778 00 COMPRESSION SPRING 1 Part Number Description Qty 23784 00 RETAINING RING 1 23786 00 PLATE 1 23787 00 FITTING 1 23788 00 HOUSING 1 23789 00 GEAR COVER F...

Page 12: ...vice be per formed on a daily basis 1 Remove gear cover p n 23789 00 and inspect valves to see if there is any leakage on the top or bottom side of the valves if there is leakage with pressure relieve...

Page 13: ...s used in two component foam and polyurea coatings ISO will react with moisture such as humidity to form small hard abrasive crystals which become suspended in the fluid Eventually a film will form on...

Page 14: ...nsert bearing p n 23768 01 into gun body 7 a Use 3 8 in twelve point socket to first snug P N 23764 00 to hand tight continue turn past snug Torque reading 20 ft lbs 88 Newton b Loosen turn and return...

Page 15: ...erence Chart Part Number Orifice 23047 J1 012 J2 014 J3 022 M1 012 M2 014 M3 022 N1 012 N2 014 N3 022 P1 012 P2 014 P3 022 Note Use p n LPA2 120G and p n LPA2 121G when using LPA2 147 XXXX and 23047 X...

Page 16: ...0 026 2665 0 026 3125 0 031 3140 0 031 3150 0 031 3165 0 031 3625 0 036 3640 0 036 3650 0 036 3840 0 038 3850 0 038 4325 0 043 4340 0 043 4350 0 043 4365 0 043 5225 0 052 Part Number Orifice LPA2 147...

Page 17: ...Air 1 4in Tube AAC Air 1 4in Tube Atomize Air 1 4in Tube A Component Catalyst Inlet Size 1 4 in Tube B Component Resin Inlet Size 1 4 18 NPS Male Sound Pressure 40 39 dB A Sound Power measured per ISO...

Page 18: ...ng but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breac...

Reviews: