background image

All written and visual data contained in this document reflects the latest product information available at the time of publication. 

Graco reserves the right to make changes at any time without notice.

Original instructions.

 This manual contains English. MM 3A5056

Graco Headquarters: 

Minneapolis

International Offices: 

Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2018, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Revision 

B

, 2019-01

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in 
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty 
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by 
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written 
recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty 
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of 
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with 
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or 
maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of 
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned 
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will 
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED 
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy 
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or 
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT 
MANUFACTURED BY GRACO

. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to 

the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these 
warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or 
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the 
negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, 
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la 
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite 
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information 

For the latest information about Graco products, visit 

www.graco.com

.

For patent information, see 

www.graco.com/patents

TO PLACE AN ORDER, 

contact your Graco distributor or call to identify the nearest distributor.

Phone: 

612-623-6921

 or Toll Free: 

1-800-328-0211

 Fax: 

612-378-3505 

Summary of Contents for G-Barrier

Page 1: ...us locations using the entity parameter concept For professional use only Not approved for use in explosive atmospheres or hazardous locations See Approvals on page 3 for approval information Important Safety Instructions Read all warnings and instructions in this manual before using the equipment Save these instructions EN 26A364 IS Power Barrier ...

Page 2: ...ion 6 Validating the Field Apparatus Entity Parameters 8 Mounting and Dismounting to DIN Rail 9 Grounding 10 Wiring the Power Input Connector 12 Wiring the Power Output Connectors 12 Airflow 13 Troubleshooting 14 Parts 14 Performance 15 Dimensions 16 Technical Specifications 17 Graco Standard Warranty 18 Graco Information 18 ...

Page 3: ... 60079 0 2019 CSA C22 2 No 60079 11 2014 CSA C22 2 No 61010 1 2012 IECEx Certification IEC 60079 0 2017 IEC 60079 11 2011 ATEX Certification EN 60079 0 2018 EN 60079 11 2012 For connection to CLASS I DIVISION 1 GROUP D USA CANADA CLASS I ZONE 0 AEx ia Ga IIA USA 0 C Ta 54 C FM18US0213 FM18CA0102 II 1 G Ex ia Ga IIA 0 C Ta 54 C IECEx FMG 18 0022 FM18ATEX0053 C US 2575 ...

Page 4: ...ision 1 Group D or Zone 0 or 1 Group IIA as applicable Hazardous Loca tion including all of the local safety fire codes For the United States this includes NFPA 33 NEC 500 and 516 and OSHA 1910 107 Equipment that comes in contact with the G Barrier s intrinsically safe terminals must be rated for Intrinsic Safety This includes DC voltage meters ohmmeters cables and connections Do not install the G...

Page 5: ...ge from 12V to 24V Regulated first stage Feedback controlled for high efficiency Overload protection against fuse damage Three independent outputs Feedback controlled for high efficiency and sta ble output Color coded and keyed output connector Temporary short circuit protection against fuse damage DIN rail mounting Ground bond screw Power Barrier Output Parameters Zones Uo Io Po Lo Co Lo Ro Divis...

Page 6: ...according to IEC 60079 14 and applicable local codes and regulations Multiple earthing of components is allowed only if a high integrity equipotential system is realized between the points of bonding The G Barrier does not provide galvanic isolation from earth or between non intrinsically safe and intrinsically safe connections Install wiring associated with intrinsically safe chan nels A B C as s...

Page 7: ...cations Class 1 Division 1 Group D US and Canada Class 1 Zone 0 or Zone 1 Group IIA US and Canada Zone 0 or Zone 1 Group IIA ATEX and IECEx FIG 1 Typical Hazardous Location Installation G Barrier To other hazardous locations Non Hazardous Location ...

Page 8: ...e defined using a combination of the symbols Ui Ii Pi Ci and Li It is pos sible that all parameters are not defined In some cases the equivalent value can be calculated Refer to the appropriate installation standards if this is the case For an installation to be valid and safe use the following calculation methods All calculation comparisons must be true FIG 2 Entity Parameters clip Parameter Zone...

Page 9: ...force of approximately 40 lbs 18 Kg force 180 N is necessary to compress the spring enough to allow the DIN rail clip to be latched onto the rail The spring must be latched behind the edge of the DIN rail to connect properly See FIG 3 To remove the device from the DIN rail pull down to compress the spring pull the bottom out to release it from the rail and lift it up off the top of the DIN rail FI...

Page 10: ...ration If the DIN rail is bonded to the system ground then the barrier connection through the DIN rail is adequate for system ground NOTE Always bond the G Barrier to the ground screw The equipment must be grounded to reduce the risk of static sparking and electric shock Improper grounding can cause electric shock Grounding pro vides an escape wire for the electric current FIG 4 Grounding Example ...

Page 11: ...Installation 3A5056B 11 FIG 5 Grounding Example 2 HAZARDOUS LOCATION NON HAZARDOUS LOCATION TO FIELD APPARATUS CLASS 2 POWER SUPPLY TO FIELD APPARATUS TO FIELD APPARATUS ...

Page 12: ...king your own cable connections the wire colors may differ Use a Class 2 Power Supply only FIG 6 Wiring Power Input Connector ca Red wire Black wire FIG 7 Wiring When Using 16K509 or 16K615 Cables FIG 8 Wiring Power Output Connectors Front View Blue Brown Black Black 1A 2A 3A 4A 5A 6A 1B 2B 3B 4B 5B 6B 1C 2C 3C 4C 5C 6C Ground Output Ground NC Ground NC Ground Output Ground NC Ground NC Ground Out...

Page 13: ...Installation 3A5056B 13 Airflow For best performance the installation must allow for air flow through and around the barrier FIG 9 Airflow ...

Page 14: ...s can be used to validate the operation of the barrier Parts Part of G Barrier Power Connector Kit 25E511 Parameter Procedure Valid Range Input Voltage Check with meter 12 VDC to 24 VDC Output Voltage with no load Check with meter 15 VDC Output Voltage with load Check with meter Compare to current from graph See Performance page 15 Output Current with load Check with meter Compare to voltage from ...

Page 15: ...int it resembles a linear barrier until it approaches an output current of 250 mA Circuitry in the barrier reduces the output voltage to protect both the internal fuse and any associated apparatus that may be shorting out As the short is released the barrier returns to linear operation and then to constant voltage operation Current mA Voltage V Current mA Power mW ...

Page 16: ...Dimensions 16 3A5056B Dimensions FIG 10 Dimensions of the G Barrier ...

Page 17: ...12 VDC Maximum input power 24 W Power supply type Class 2 Environmental Parameters Ambient temperature range 32 F Ta 129 F 0 C Ta 54 C Humidity 0 to 90 Clearance above unit 1 in 25 mm Clearance to side of unit 1 4 in 6 mm Clearance below unit 1 2 in 12 mm Enclosure material Aluminum Anodized aluminum Weight 1 lb 1000 g Width 2 in 50 mm Height 5 in 125 mm Depth 4 in 100 mm ...

Page 18: ...aterial or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warrant...

Reviews: