Digital Display
332255A
15
Digital Display
1.
Follow P
ressure Relief Procedure
, page 8.
2.
Plug sprayer in to grounded outlet. Turn power
ON.
3.
The pressure is displayed. Dashes indicate pres-
sure is less than 200 psi (14 bar, 1.4MPa).
4.
Press and hold display button to change pressure
units (psi, bar or MPa).
Stored Data
1.
Turn power
OFF
.
2.
While pressing display button, turn power
ON
to
enter Stored Data mode.
3.
Model number is displayed and then Data Point 1,
power on time in hours, is displayed.
NOTE:
FT600 = 595.
4.
Press display button to display Data Point 2, motor
on time in hours.
5.
Press display button to display Data Point 3, last
error code. Press and hold display button to erase
last error code.
6.
Press display button to display Data Point 4,
software revision.
7.
Press display button again to return to Data Point 1.
Turn power
OFF
to exit Stored Data.
ti2706a