Cleanup 

14

332255A

10. Raise siphon tube above flushing fluid and run 

sprayer for 15 to 30 seconds to drain fluid. Turn 
power 

OFF

11. Close drain valve. Trigger gun into flushing pail to 

purge fluid from hose.

12. Open prime valve.

13. Remove filters from gun and sprayer, if installed. 

Clean and inspect. Install filters.

14. If flushing with water, flush again with mineral spir-

its, or Pump Armor, to leave a protective coating to 
prevent freezing or corrosion.

15. Wipe sprayer, hose and gun with a rag soaked in 

water or mineral spirits.

ti2707a

PAINT

FLUSH

ti2820a

ti2712a

WASTE

ti2713a

ti2719a

ti2814a

Pump Armor

ti2895a

ti2776a

Summary of Contents for FT600 278680

Page 1: ...the application of architectural paints and coatings For professional use only Model 278680 3300 psi 227 bar 22 7 MPa Maximum Working Pressure IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instr...

Page 2: ...Requirements 6 Extension Cords 6 Pails 7 Pressure Relief Procedure 8 Setup 9 Startup 10 Tip and Guard Assembly 11 Spraying 11 Clearing Clog 12 Cleanup 13 Digital Display 15 Main Menu Operation 16 Sec...

Page 3: ...static discharge Do not use pail liners unless they are are antistatic or conductive Connect to a grounded outlet and use grounded extensions cords Do not use a 3 to 2 adapter Do not use a paint or a...

Page 4: ...t parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for the environment in whic...

Page 5: ...tion H J K M N S T P R F E D B C ps A G A Pressure control B Power Cord C ON OFF switch D Digital Display E Prime Spray valve F Filter G Fluid outlet H Siphon tube J Drain tube K Pump M Hose N Spray G...

Page 6: ...ontainer follow local code Object being sprayed follow local code Power Requirements 230V units require 220 240 VAC 50 60 Hz 8A 1 phase Extension Cords If an extension cord is necessary use a 3 wire 1...

Page 7: ...uch as paper or cardboard which interrupts grounding continuity Grounding a metal pail connect a ground wire to the pail by clamping one end to pail and other end to a true earth ground such as a wate...

Page 8: ...been fully relieved after following these steps VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually then loosen completely Now clear tip or hose obstruction...

Page 9: ...er OFF 8 Plug power supply cord into a properly grounded electrical outlet 9 Turn prime valve down 10 Place siphon tube set in grounded metal pail par tially filled with flushing fluid Attach ground w...

Page 10: ...leaks with hand or a rag If leaks occur do Pressure Relief Tighten fit tings Do Startup 1 5 page 10 If no leaks pro ceed to 6 7 Place siphon tube in paint pail 8 Trigger gun again into flushing pail u...

Page 11: ...sure adjustment can not eliminate heavy edges 2 Hold gun perpendicular 10 12 in from surface Spray back and forth overlapping by 50 To pre vent heavy spots before pulling trigger first move gun using...

Page 12: ...er put safety ON 2 Rotate SwitchTip 3 Take safety OFF 4 Trigger gun to clear clog Never point gun at your hand or into a rag 5 Put safety ON 6 Return Switch to original position 7 Take safety OFF and...

Page 13: ...ower ON Turn prime valve horizontal 7 Hold gun against paint pail Take trigger safety OFF Trigger gun and increase pressure until flushing fluid appears 8 Move gun to flushing pail hold gun against pa...

Page 14: ...Open prime valve 13 Remove filters from gun and sprayer if installed Clean and inspect Install filters 14 If flushing with water flush again with mineral spir its or Pump Armor to leave a protective c...

Page 15: ...tton turn power ON to enter Stored Data mode 3 Model number is displayed and then Data Point 1 power on time in hours is displayed NOTE FT600 595 4 Press display button to display Data Point 2 motor o...

Page 16: ...s x 10 5 NOTE LIFE displays briefly then the number of gal lons sprayed above 1000 psi 70 bar 7 MPa Secondary Menu 1 Follow Pressure Relief Procedure page 8 2 Press DTS button and turn power switch ON...

Page 17: ...0 Hz 230V 1 phase 10A 50 60 Hz Dimensions Weight 72 lb 33 kg Length 21 in 53 3 cm Width 20 5 in 52 1 cm Height Handle Up 39 5 in Handle Down 29 5 in Handle Up 100 3 cm Handle Down 74 9 cm Basic Wetted...

Page 18: ...tion prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and t...