16
308219
Installation
11. Adjust the Heater
1.
Measure the incoming voltage on the junction box
power in terminal block from pins 1 to 2, pins 3 to
4, and pins 5 to 6. See Fig. 10 or 11, pages 21 and
23. Voltage must read 200 to 240 VAC rms
between each set of pins.
2.
Set all three Temperature Set dials (K) to
CAL
.
See Fig. 8.
3.
Turn the circuit breakers (210 and 319) to
I
(ON
)
.
See Fig. 8.
4.
Check that the input voltage is still correct.
5.
The heater lamps should blink within 10 seconds
after turning on the circuit breakers. With fluid
flowing only, check the heater thermometers (204)
regularly and manually adjust the fluid temperature
as needed. See Fig. 8.
6.
The heated hose control lamp should start blinking
soon after turning on the circuit breaker. The
duration of ON versus OFF time indicates power
applied.
NOTE:
If the lamps do not start blinking in the time
specified above, check for possible problems and
solutions in the Troubleshooting guide, starting on
page 18.
7.
If using a heated hose control, test the Ground
Fault Interrupter (GFI) daily. To test, depress the
button (N). See Fig. 8. If the circuit breaker shuts
off, the GFI is working properly.
01691
Fig. 8
K
210
319
N
204