Installation
6.
Connect the Electrical Service
WARNING
ELECTRIC SHOCK HAZARD
To reduce the risk of serious injury,
including electric shock, all electrical
wiring must be done by trained and
qualified personnel and comply with all local codes
and regulations.
The electrical requirements for the heater and heated
hose controls and the wiring diagram are shown on the
inside cover of the junction box (233). Wire the heater
to your electrical service. Three jumper wires are
included.
This is the information on the label (205) under the
junction box cover.
38 Amps
38 Amps
38 Amps
22 Amps
22 Amps
22 Amps
22 Amps
16 Amps
16 Amps
L1
L2
L3
RES
HTR
5.1 Kw
ISO
HTR
5.1 Kw
HOSE
3.8 Kw
(max)
TB1
TB2
TB3
TB4
TB5
TB6
60 Amps
60 Amps
22 Amps
22 Amps
22 Amps
22 Amps
16 Amps
16 Amps
L1
L2
TB1
TB2
TB3
TB4
TB5
TB6
RES
HTR
5.1 Kw
ISO
HTR
5.1 Kw
HOSE
3.8 Kw
(max)
Model 235260
3 phase, 240 VAC
Model 235260
1 phase, 240 VAC
28 Amps
28 Amps
28 Amps
11 Amps
11 Amps
11 Amps
11 Amps
16 Amps
16 Amps
L1
L2
L3
RES
HTR
2.6 Kw
ISO
HTR
2.6 Kw
HOSE
3.8 Kw
(max)
TB1
TB2
TB3
TB4
TB5
TB6
Model 235259
3 phase, 240 VAC
38 Amps
38 Amps
11 Amps
11 Amps
11 Amps
11 Amps
16 Amps
16 Amps
Lx
Ly
TB1
TB2
TB3
TB4
TB5
TB6
RES
HTR
2.6 Kw
ISO
HTR
2.6 Kw
HOSE
3.8 Kw
(max)
Model 235259
1 phase, 240 VAC
38 Amps
38 Amps
38 Amps
22 Amps
22 Amps
22 Amps
22 Amps
L1
L2
L3
RES
HTR
5.1 Kw
ISO
HTR
5.1 Kw
TB1
TB2
TB3
TB4
Model 235840
3 phase, 240 VAC
Model 235260
1 phase, 240 VAC
44 Amps
44 Amps
22 Amps
22 Amps
22 Amps
22 Amps
L1
L2
RES
HTR
5.1 Kw
ISO
HTR
5.1 Kw
TB1
TB2
TB3
TB4
19 Amps
19 Amps
19 Amps
11 Amps
11 Amps
11 Amps
11 Amps
L1
L2
L3
RES
HTR
2.6 Kw
ISO
HTR
2.6 Kw
TB1
TB2
TB3
TB4
Model 235839
3 phase, 240 VAC
Model 235839
1 phase, 240 VAC
22 Amps
22 Amps
11 Amps
11 Amps
11 Amps
11 Amps
L1
L2
RES
HTR
2.6 Kw
ISO
HTR
2.6 Kw
TB1
TB2
TB3
TB4
FOAM–CAT 400
FOAM–CAT 200
FOAM–CAT 200
FOAM–CAT 400
FOAM–CAT 400
FOAM–CAT 400
FOAM–CAT 200
FOAM–CAT 200