1.
Apply anaerobic pipe sealant to all
non-swiveling pipe threads.
3
Ensure that the fan (9) direction arrow points
away from the mounting panel.
4
Install pulley (45) flush with motor shaft (43).
5
Install pulley (44) overhung on pump shaft
(27) by .18 +/- .03 in. On models 17H031,
17H032, and 17H074: Install pulley (49) .49
+/- .03 in. from pump shaft (27) end.