10 308382
Installation
Model 244085, Universal Pump
1.
See Fig. 2. Assemble the air regulator kit (items
3a–3d) to the pump air inlet (A), as shown. Use
thread sealant and tighten all parts securely.
2.
Apply thread sealant to the male threads of the 3/8
npt swivel union (2b). Screw the union into the
bleed-type master air valve (3c).
3.
Apply thread sealant to the male threads of the 1/2
npt swivel union (2d). Screw the union into the
pump fluid outlet (B).
4.
Connect the 1/2 npt(mbe) fluid hose (2c) to the
swivel union (2d).
5.
Connect the 3/8 npt(mbe) air hose (2a) to the
swivel union (2b).
Fig. 2
1
3a
3b
3c
3d
2a
2b
2c
2d
Apply thread sealant.
1
A
1
1
B
Install ground wire 222011 (required)
here. See Fig. 1 on page 9.
2
2
Thermal Relief
Kit 235998
(recommended)
03391B
3b
1
Summary of Contents for FALCON 244085