background image

Warnings

Warnings

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific
risks. When these symbols appear in the body of this manual or on warning labels, refer back to these
Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout
the body of this manual where applicable.

WARNING

WARNING

WARNING

FIRE

FIRE

FIRE AND

AND

AND EXPLOSION

EXPLOSION

EXPLOSION HAZARD

HAZARD

HAZARD

Flammable fumes, such as solvent and paint fumes, in work

work

work area

area

area can ignite or explode.

Paint or solvent flowing through the equipment can cause static sparking. To help prevent
fire and explosion:

• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps,

and plastic drop cloths (potential static sparking).

• Ground all equipment in the work area. See Grounding

Grounding

Grounding instructions.

• Never spray or flush solvent at high pressure.
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when

flammable fumes are present.

• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners

unless they are anti-static or conductive.

• Stop

Stop

Stop operation

operation

operation immediately

immediately

immediately if static sparking occurs or you feel a shock. Do not use

equipment until you identify and correct the problem.

• Keep a working fire extinguisher in the work area.

Static charge may build up on plastic parts during cleaning and could discharge and ignite
flammable vapors. To help prevent fire and explosion:

• Clean plastic parts only in well ventilated area.

• Do not clean with a dry cloth.

• Do not operate electrostatic guns in equipment work area.

SPECIAL

SPECIAL

SPECIAL CONDITIONS

CONDITIONS

CONDITIONS FOR

FOR

FOR SAFE

SAFE

SAFE USE

USE

USE

• To prevent the risk of electrostatic sparking, the equipment’s non-metallic parts should

be cleaned only with a damp cloth.

• The aluminum housing may spark upon impact or contact with moving parts, which may

cause fire or explosion. Take precautions to avoid such impact or contact.

• All flameproof joints are critical to the integrity of the driver as approved for hazardous

locations and are not repairable if damaged. Damaged parts must be replaced only with
genuine Graco parts with no substitutions.

• Consult Graco Technical Assistance or your Graco distributor if dimensional information

on the flameproof joints is necessary.

• Consult Graco Technical Assistance or your Graco distributor for genuine replacement

fasteners. M8 x 30 socket-head cap screws of Class 12.9 steel or better with a minimum
yield strength of 1100 MPa (160,000 psi) are acceptable alternatives. All socket-head
cap screw cover fasteners must be torqued to 15 ft-lb (20.3 N•m).

4

3A3165H

Summary of Contents for Ex35

Page 1: ...protective protective coatings coatings coatings using using using e e e Xtreme Xtreme Xtreme Sprayers Sprayers Sprayers For For For professional professional professional use use use only only only...

Page 2: ...ver Model 3 Related Manuals 3 Warnings 4 Component Identification 7 Installation 8 Power Supply Requirements 8 Hazardous Area Cabling and Conduit Requirements 8 Grounding 9 Connect Power 10 General Re...

Page 3: ...Ex d IIA T4 Gb 5 C Ta 50 CFM20CA0054X List List List of of of Standards Standards Standards IEC 60079 0 IEC 60079 1 EN 60079 0 EN 60079 1 ANSI ISA 60079 0 ANSI UL 60079 1 FM 3600 FM 3615 FM 3810 CSA...

Page 4: ...less they are anti static or conductive Stop Stop Stop operation operation operation immediately immediately immediately if static sparking occurs or you feel a shock Do not use equipment until you id...

Page 5: ...e guards or covers removed Pressurized equipment can start without warning Before checking moving or servicing equipment follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure...

Page 6: ...onent See Technical Technical Technical Specifications Specifications Specifications in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Tech...

Page 7: ...on Description Description A Driver C Lift Ring G Oil Drain Plug H Driver Output Shaft K Oil Sight Glass L Status Indicator Light LED N Pressure Control Knob P Oil Fill Cap vented S Power Switch Lock...

Page 8: ...rcuit breaker Model Model Model Voltage Voltage Voltage Phase Phase Phase Hz Hz Hz kVA kVA kVA 24X901 200 240 Vac 1 50 60 2 5 NOTE NOTE NOTE The protective earthing ground conductor must be equal to t...

Page 9: ...ire for the electric current Driver Driver Driver The driver is grounded through the power cord Driver Driver Driver optional optional optional secondary secondary secondary Pump Ground Wire Two groun...

Page 10: ...eal D is required within 18 in 457 mm of the driver for the US and Canada 4 15 in lb maximum terminal bushings 2 To install wiring locate the electrical junction box Y Remove four screws J and junctio...

Page 11: ...ipment power and shut off power at the main circuit breaker before repairing Wear appropriate protective equipment when in work area Wait five minutes before servicing Make sure wires are not pinched...

Page 12: ...on Graco reserves the right to make changes at any time without notice Original Instructions This manual contains English MM 3A3165 3A3165 3A3165 Graco Graco Graco Headquarters Headquarters Headquarte...

Reviews: