Model Information

Model

Model

Model Information

Information

Information

Driver

Driver

Driver Model

Model

Model

Part

Part

Part

Series

Series

Series

Description

Description

Description

Weight

Weight

Weight

24X901

B

e-Xtreme Driver

110 lb (50 kg)

2575

2575

2575

II 2 G

Ex db IIA T4 Gb -5°C≤Ta≤50°C
FM15ATEX0060X
IECEx FMG 15.0035X

For Class I, Div. 1, Group D T4.

Zone 1, AEx db IIA T4 Gb -5°C≤Ta≤50°C
Ex d IIA T4 Gb -5°C≤Ta≤50°CFM20CA0054X

List

List

List of

of

of Standards

Standards

Standards

• IEC 60079–0

• IEC 60079–1

• EN 60079–0

• EN 60079–1

• ANSI/ISA 60079–0

• ANSI/UL 60079–1

• FM 3600

• FM 3615

• FM 3810

• CSA C22.2 No. 0.4

• CSA C22.2 No. 0.5

• CSA C22.2 No. 30

• CAN/CSA C22.2 60079–0

• CAN/CSA C22.2 60079–1

• CAN/CSA C22.2 No. 61010.1

Related

Related

Related Manuals

Manuals

Manuals

Manual

Manual

Manual in

in

in

English

English

English

Description

Description

Description

3A5124

e-Xtreme Driver Operation, Repair
and Troubleshooting

3A3164

e-Xtreme Ex35/Ex45 Sprayer

311619

Pump Mounting Kit Manual

3A3165H

3

Summary of Contents for Ex35

Page 1: ...protective protective coatings coatings coatings using using using e e e Xtreme Xtreme Xtreme Sprayers Sprayers Sprayers For For For professional professional professional use use use only only only...

Page 2: ...ver Model 3 Related Manuals 3 Warnings 4 Component Identification 7 Installation 8 Power Supply Requirements 8 Hazardous Area Cabling and Conduit Requirements 8 Grounding 9 Connect Power 10 General Re...

Page 3: ...Ex d IIA T4 Gb 5 C Ta 50 CFM20CA0054X List List List of of of Standards Standards Standards IEC 60079 0 IEC 60079 1 EN 60079 0 EN 60079 1 ANSI ISA 60079 0 ANSI UL 60079 1 FM 3600 FM 3615 FM 3810 CSA...

Page 4: ...less they are anti static or conductive Stop Stop Stop operation operation operation immediately immediately immediately if static sparking occurs or you feel a shock Do not use equipment until you id...

Page 5: ...e guards or covers removed Pressurized equipment can start without warning Before checking moving or servicing equipment follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure...

Page 6: ...onent See Technical Technical Technical Specifications Specifications Specifications in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Tech...

Page 7: ...on Description Description A Driver C Lift Ring G Oil Drain Plug H Driver Output Shaft K Oil Sight Glass L Status Indicator Light LED N Pressure Control Knob P Oil Fill Cap vented S Power Switch Lock...

Page 8: ...rcuit breaker Model Model Model Voltage Voltage Voltage Phase Phase Phase Hz Hz Hz kVA kVA kVA 24X901 200 240 Vac 1 50 60 2 5 NOTE NOTE NOTE The protective earthing ground conductor must be equal to t...

Page 9: ...ire for the electric current Driver Driver Driver The driver is grounded through the power cord Driver Driver Driver optional optional optional secondary secondary secondary Pump Ground Wire Two groun...

Page 10: ...eal D is required within 18 in 457 mm of the driver for the US and Canada 4 15 in lb maximum terminal bushings 2 To install wiring locate the electrical junction box Y Remove four screws J and junctio...

Page 11: ...ipment power and shut off power at the main circuit breaker before repairing Wear appropriate protective equipment when in work area Wait five minutes before servicing Make sure wires are not pinched...

Page 12: ...on Graco reserves the right to make changes at any time without notice Original Instructions This manual contains English MM 3A3165 3A3165 3A3165 Graco Graco Graco Headquarters Headquarters Headquarte...

Reviews: