I/O Integration
64
3A6165J
Remote Sequence Selection
The active sequence can be changed using Connector
#1 (AP) on the ADM. Selection bits are pulled high by
default and must be dropped low to select the desired
sequence.
Foot Switch Connection
Connect the foot switch (255244) by plugging the 5 pin
female connector of cable 17Z431 to the foot switch
connector. If the I/O integration cable (128441) is also
desired, connect the splitter (127948) to connector 4 of
the EFR, then connect the integration cable (128441)
and cable 17Z431 to the splitter. If the I/O integration
cable is not desired, connect cable 17Z431 to connector
4 of the EFR.
Sequence
Number
Selected
Sequence
Selection
BIT0
(Conn. #1,
Pin #1)
Sequence
Selection
BIT1
(Conn. #1,
Pin #2)
Sequence
Selection
BIT2
(Conn. #1,
Pin #4)
Sequence
Selection
BIT3
(Conn. #1,
Pin #5)
None /
Display
Module
Selection
High
High
High
High
1
Low
High
High
High
2
High
Low
High
High
3
Low
Low
High
High
4
High
High
Low
High
5
Low
High
Low
High
6
High
Low
Low
High
7
Low
Low
Low
High
8
High
High
High
Low
9
Low
High
High
Low
10
High
Low
High
Low
11
Low
Low
High
Low
12
High
High
Low
Low
13
Low
High
Low
Low
14
High
Low
Low
Low
15
Low
Low
Low
Low
Brown
Gray
Black
Blue
White
2
3
1
5
4
SHOT SEL - BIT 0
SHOT SEL - BIT 2
SHOT SEL - BIT 3
SHOT SEL - BIT 1
COMMON
ADM Connector #1 (AP)
NOTE:
The view shown looking at the pins on the end