background image

Infra Red Basin Tap

IR180CP.1 Battery Operated

Installation and Maintenance Instructions

In this procedure document we have endeavoured to make the
information as accurate as possible.
We cannot accept any responsibility should it be found that in
any  respect  the  information  is  inaccurate  or  incomplete  or
becomes so as a result of further developments or otherwise.

Intatec Ltd

Airfield Industrial Estate

Hixon

Staffordshire

ST18  0PF

Tel: 

01889 272 180

Fax: 

01889 272 181

email: 

[email protected]

web:  

www.intatec.co.uk

© Intatec Ltd. 2015

Summary of Contents for IR180CP.1

Page 1: ...urate as possible We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further developments or otherwise Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF Tel 01889 272 180 Fax 01889 272 181 email sales intatec co uk web www intatec co uk Intatec Ltd 2015 ...

Page 2: ...8 472 791 Products Infra Red Basin Tap IR180CP 1 Check Content Before commencing remove all components from packaging and check each component with the contents list Ensure all parts are present before discarding any packaging If any parts are missing do not attempt to install your Inta shower valve until the missing parts have been obtained Technical Data Operating water pressure range 1 to 8 bar...

Page 3: ... Intatec Ltd 2015 2 Dimensions 108 56 G 119 137 60 40 5 39 70 ...

Page 4: ...3 Item Qty Component Item Qty Component 1 1 Tap 5 2 Stainless steel flexible hose 2 1 Fixing kit 6 2 Inlet nut 3 1 Battery box 7 2 Sealing washer 4 2 Wall plug and fixing screw 8 1 Power cable Components 2 5 7 6 8 3 4 1 ...

Page 5: ... Flush the water supply pipes thoroughly prior to installation Do not allow debris PTFE tape or any metal particles to enter the tap Turn off the water supply Important All plumbing to be installed in accordance with applicable codes and regulations Installation FAILURE TO OBSERVE THE INSTALLATION INSTRUCTIONS WILL INVALIDATE THE PRODUCT WARRANTY CONDITION 1 Screw the flexible hoses 5 into the inl...

Page 6: ...d This new setting will be stored in case of battery replacement or lacking of electricity Safety Device To prevent flooding of the premises following an act of vandalism or misuse an object left in front of the sensor or a dirty sensor the tap has a safety device that shuts off the water flow after about one minute Once the object has been removed or the sensor has been cleaned the tap starts wor...

Page 7: ...queries should further assistance be required our Technical Department can be contacted directly on 01889 272199 Fault Cause Solution No water flow The isolation valves are closed Open the isolation valves Exhausted battery LED flashes Replace the battery Electrical problem Check the voltage Disconnect and reconnect the battery where applicable Check the connections and the cable s integrity Damag...

Page 8: ... at its option to repair or replace any faults caused by defective material or manufacturing that may arise see Intatec Warranty The warranty does not cover dame caused by Abnormal or improper use Incorrect installation or water system problems Normal wear or negligence in maintenance and in use Acts of vandalism Contact with abrasives corrosive chemicals or unsuitable cleaning agents or instrumen...

Reviews: