Performance
Performance
Performance Charts
Charts
Charts
To find the fluid pressure (psi/bar/MPa) at a specific
fluid flow (gpm/lpm) and percentage of maximum
force:
1.
Locate the desired fluid flow in the scale at the
bottom of the chart.
2.
Follow the vertical line up to the intersection with
the selected percentage of maximum force (see
the Key
Key
Key below).
3.
Follow left to the vertical scale to read the fluid
outlet pressure.
Key
Key
Key to
to
to Performance
Performance
Performance Charts
Charts
Charts
NOTE:
NOTE:
NOTE: The charts show the motor operating at
100%, 70%, and 40% of maximum force. These
values are approximately equivalent to an air motor
operating at 100, 70, and 40 psi.
A
40% single phase
B
40% three phase
C
70% single phase
D
70% three phase
E
100% single phase
F
100% three phase
Table
Table
Table 2
2
2 ... E
E
E---Flo
Flo
Flo DC
DC
DC with
with
with Dura
Dura
Dura---Flo
Flo
Flo 145
145
145 Lower
Lower
Lower
CYCLES
CYCLES
CYCLES PER
PER
PER MINUTE
MINUTE
MINUTE
0
400
(2.8, 28)
800
(5.5, 55)
1200
(8.3, 83)
1600
(10.0, 1 10)
2000
(13.8, 138)
2400
(16.6, 166)
2800
(19.3, 193)
3200
(22.1, 221)
3600
(24.8, 248)
4000
(27.6, 276)
4400
(30.3, 303)
0.0
0.1
(0.38)
0.2
(0.76)
0.3
(1.14)
0.4
(1.52)
0.5
(1.90)
0.6
(2.28)
0.7
(2.66)
0.8
(3.04)
3
8
14
21
0.9
(3.42)
1.0
(3.80)
A
B
C
D
E
F
FLUID
FLUID
FLUID
PRESSURE:
PRESSURE:
PRESSURE:
psi (bar, MPa)
FLUID
FLUID
FLUID FLOW:
FLOW:
FLOW: gpm (lpm)
32
333389E